Practice Questions And Correct Answers
(Verified Answers) Plus Rationales
2025|2026 Q&A | Instant Download Pdf
1. What is the minimum insulation resistance required for a 480-volt
trailing cable in a coal mine?
a) 100,000 ohms
b) 1 megohm
c) 500 ohms
d) 10 megohms
Insulation resistance of trailing cables must be at least 1 megohm for
safety against shock and fire hazards.
2. What device is required to automatically de-energize a circuit in case
of ground fault in underground mines?
a) Transformer
b) Circuit breaker
, c) Ground fault relay
d) Fuse
Ground fault relays are required to trip circuits to prevent shock
hazards when faults occur.
3. Which of the following is used to reduce arc flash hazards when
working with electrical equipment?
a) Removing grounding
b) Using personal protective equipment (PPE)
c) Increasing voltage
d) Wetting the area
PPE such as arc-rated clothing reduces burn injury during arc flash
events.
4. In direct current (DC) circuits, which unit measures electrical current?
a) Volts
b) Amperes
c) Watts
d) Ohms
Current is measured in amperes, representing the flow of charge per
second.
5. What is the primary function of a circuit breaker?
a) To store electrical energy
b) To interrupt current flow in case of overload or fault
c) To increase voltage
, d) To reduce resistance
Circuit breakers protect wiring and equipment by automatically
opening during faults.
6. What is the color coding requirement for ground conductors in mine
trailing cables?
a) Red
b) Black
c) Green or green with yellow stripes
d) Blue
Ground conductors are identified by green insulation for safety and
standardization.
7. Which law states that current is directly proportional to voltage and
inversely proportional to resistance?
a) Faraday’s Law
b) Coulomb’s Law
c) Ohm’s Law
d) Newton’s Law
Ohm’s Law: I = V/R is fundamental to electrical calculations.
8. What is the purpose of flame-resistant trailing cables in mines?
a) To reduce cable weight
b) To increase flexibility
c) To prevent fire propagation
d) To reduce cost
, Flame-resistant insulation prevents fire spread in hazardous
environments like coal mines.
9. Which instrument is most appropriate for checking continuity in a
circuit?
a) Wattmeter
b) Ohmmeter
c) Ammeter
d) Voltmeter
An ohmmeter checks for continuity by measuring resistance across
circuit points.
10. How often must circuit breakers in coal mines be tested?
a) Daily
b) Weekly
c) Monthly
d) Annually
Regulations require monthly testing of circuit breakers to ensure
reliability.
11. What is the purpose of a lockout/tagout procedure?
a) Speed up maintenance
b) Ensure equipment is de-energized and cannot be restarted during
work
c) Improve voltage output