Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

EDELMAN SPI EXAM /EDELMAN SPI EXAM PREPARATION/EDELMAN SPI PRACTICE EXAM WITH QUESTIONS AND CORRECT ANSWERS| BRAND NEW VERSION!

Beoordeling
-
Verkocht
-
Pagina's
120
Cijfer
A+
Geüpload op
13-10-2025
Geschreven in
2025/2026

EDELMAN SPI EXAM /EDELMAN SPI EXAM PREPARATION/EDELMAN SPI PRACTICE EXAM WITH QUESTIONS AND CORRECT ANSWERS| BRAND NEW VERSION! Which of the following situations should result in a cessation of the use of diagnostic ultrasound? a: the presence of transient cavitation b: when tissue temperature is more than 1 degree Centigrade above normal c: the benefit outweighs the risk. d: when a pregnant mother has a very high fever e: the benefits are outweighed by the risks. - Correct Answer-e: the benefits are outweighed by the risks. A sound wave with a frequency of 5 MHz is travelling in soft tissue. What is the wavelength of this sound? a: 0.5 mm b: 0.3 cm c: 5 mm d: 0.3 mm - Correct Answer-d: 0.3 mm All the following correctly describe dynamic range EXCEPT: a: relative b: ratio c: absolute 2 | Page Edelman SPI Exam /Edelman SPI Exam Preparation/Edelman SPI Practice Exam d: comparison e: logarhythmic - Correct Answer-c: absolute All the following will improve temporal resolution EXCEPT: a: slower speed of sound in a medium b: increased line density c: single rather than multi focus d: higher frame rate - Correct Answer-b: increased line density Which of these choices has the greatest effect upon depth of view? a: pulse repetition period b: transducer output c: acoustic impedance d: pulse duration e: spatial pulse length - Correct Answer-a: pulse repetition period What is the accuracy of reflector depth position on an A-mode, B-mode or M mode display called? a: axial resolution b: speed error artifact c: range resolution d: horizontal calibration e: depth calibration - Correct Answer-e: depth calibration 3 | Page Edelman SPI Exam /Edelman SPI Exam Preparation/Edelman SPI Practice Exam All the following are true EXCEPT: a: Out-of-phase waves interfere destructively. b: Constructive interference is associated with waves that are in-phase. c: Waves of different frequencies may exhibit both constructive and destructive interference at different times. d: Two waves with identical frequencies must interfere constructively - Correct Answer-d: Two waves with identical frequencies must interfere constructively

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Edelman SPI Exam /Edelman SPI Exam Preparation/Edelman SPI Practice
Exam


EDELMAN SPI EXAM /EDELMAN SPI EXAM
PREPARATION/EDELMAN SPI PRACTICE EXAM WITH QUESTIONS
AND CORRECT ANSWERS| BRAND NEW VERSION!
Which of the following situations should result in a cessation of the use of
diagnostic ultrasound?
a: the presence of transient cavitation
b: when tissue temperature is more than 1 degree Centigrade above normal
c: the benefit outweighs the risk.
d: when a pregnant mother has a very high fever
e: the benefits are outweighed by the risks. - Correct Answer-e: the benefits are
outweighed by the risks.


A sound wave with a frequency of 5 MHz is travelling in soft tissue. What is the
wavelength of this sound?
a: 0.5 mm
b: 0.3 cm
c: 5 mm
d: 0.3 mm - Correct Answer-d: 0.3 mm


All the following correctly describe dynamic range EXCEPT:
a: relative
b: ratio
c: absolute
1|Page

, Edelman SPI Exam /Edelman SPI Exam Preparation/Edelman SPI Practice
Exam

d: comparison
e: logarhythmic - Correct Answer-c: absolute


All the following will improve temporal resolution EXCEPT:
a: slower speed of sound in a medium
b: increased line density
c: single rather than multi focus
d: higher frame rate - Correct Answer-b: increased line density


Which of these choices has the greatest effect upon depth of view?
a: pulse repetition period
b: transducer output
c: acoustic impedance
d: pulse duration
e: spatial pulse length - Correct Answer-a: pulse repetition period


What is the accuracy of reflector depth position on an A-mode, B-mode or M-
mode display called?
a: axial resolution
b: speed error artifact
c: range resolution
d: horizontal calibration
e: depth calibration - Correct Answer-e: depth calibration
2|Page

, Edelman SPI Exam /Edelman SPI Exam Preparation/Edelman SPI Practice
Exam



All the following are true EXCEPT:
a: Out-of-phase waves interfere destructively.
b: Constructive interference is associated with waves that are in-phase.
c: Waves of different frequencies may exhibit both constructive and destructive
interference at different times.
d: Two waves with identical frequencies must interfere constructively - Correct
Answer-d: Two waves with identical frequencies must interfere constructively


What is the maximum number of shades of gray that can be represented by 5
bits?
a: 32 shades
b: 64 shades
c: 10 shades - Correct Answer-a: 32 shades


How much bigger is a billion (9 zeroes) than a thousand (3 zeroes)?
a: 1,000,000,000
b: 1,000
c: 100
d: 1,000,000
e: 10,000 - Correct Answer-d: 1,000,000


You are performing a quality assurance study on an ultrasound system using a
tissue equivalent phantom. You make an adjustment using a knob on the system
3|Page

, Edelman SPI Exam /Edelman SPI Exam Preparation/Edelman SPI Practice
Exam

console that changes the appearance of reflector brightness from fully bright to
barely visible. What are you evaluating?
a: system sensitivity
b: vertical calibration
c: dynamic range
d: slice thickness
e: resolution - Correct Answer-a: system sensitivity


Which of the following factors determine the spatial resolution of a monitor?
a: the number of pixels per bit
b: the number of lines per frame
c: dynamic range
d:: the number of bits per inch
e: the number pixels per inch - Correct Answer-b: the number of lines per frame


Which of the following statement about Doppler is most correct?
Non directional doppler uses phase-singular processing while bi-directional uses?
a: non-directional Doppler uses phase-singular processing, while bi-directional
Doppler uses phase-quadrature processing.
b: non-directional Doppler uses non-coherent processing, while bi-directional
Doppler uses phase-quadrature processing
c: non-directional Doppler uses autocorrelation processing, while bi-directional
Doppler uses phase-quadrature processing. - Correct Answer-b: non-directional


4|Page

Geschreven voor

Vak

Documentinformatie

Geüpload op
13 oktober 2025
Aantal pagina's
120
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SophiaBennettRN Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
24
Lid sinds
1 jaar
Aantal volgers
1
Documenten
2262
Laatst verkocht
1 week geleden
TopGrade Tutor: Expert Psychology, Nursing, Pharmacology & Computer and Math Resources

Welcome to my academic support store, your trusted destination for top-tier homework help and tutoring services! Specializing in key subjects like Psychology, Nursing, Human Resource Management, and Mathematics, I’m dedicated to helping students excel with high-quality, meticulously crafted resources. My mission is to deliver scholarly, reliable content that guarantees excellent grades, earning me a reputation as one of Stuvia’s BEST GOLD RATED TUTORS. Whether you need assistance with quizzes, exams, or detailed study materials, I prioritize your success with a commitment to academic excellence and results you can count on

Lees meer Lees minder
3.9

7 beoordelingen

5
4
4
1
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen