NATE EXAM: AIR CONDITIONING AND HEAT PUMPS NEWEST EXAM / NATE AIR CONDITIONING AND HEAT PUMPS PREPARATION/NATE AIR CONDITIONING AND HEAT PUMPS EXAM PRACTICE EXAM WITH 150 QUESTIONS AND CORRECT ANSWERS| BRAND NEW VERSION! Why are more circuits needed in the outdoor coils used in heat pumps than in the condenser coils used in cooling-only units? a. To keep the pressure drop across the outdoor coil high b. To keep the pressure drop across the outdoor coil low c. To provide more subcooling during the cooling cycle d. To provide more subcooling during the heating cycle - Correct Answer-b (To keep the pressure drop across the outdoor coil low) What is the typical water flow rate per ton of cooling for water-source heat pumps operating in closed-loop systems? a. 3.0 gpm per ton b. 2.5 gpm per ton c. 2.0 gpm per ton d. 1.5 gpm per ton - Correct Answer-a (3.0 gpm per ton) What tool should be used to shorten a capillary tube? 2 | Page NATE Exam: Air Conditioning and Heat Pumps Newest Exam / NATE Air Conditioning and Heat Pumps Preparation a. A pair of pliers with side-cutter edges b. A small tubing cutter c. Any tubing cutter approved for use on refrigerant tubing d. A triangular or knife-edge file - Correct Answer-d (A triangular or knife-edge file) Which pressure in a TEV is the opening pressure? a. Bulb pressure b. Evaporator pressure c. Spring pressure d. A combination of bulb and spring pressures - Correct Answer-a (Bulb pressure) What affect does a low refrigerant charge have on reversing valve operation? a. It causes the slider to overheat b. It creates a hissing sound in the reversing valve c. It increases the chance that the reversing valve will not be able to transfer properly d. It has no effect on reversing valve operation - Correct Answer-c (It increases the chance that the reversing valve will not be able to transfer properly) When adding a heat pump to an existing fossil-fuel furnace, an installer must do all of the following except ____. 3 | Page NATE Exam: Air Conditioning and Heat Pumps Newest Exam / NATE Air Conditioning and Heat Pumps Preparation a. add a control to prevent the heat pump and furnace from operating at the same time during normal heating b. confirm there is adequate clearance around the outdoor section for good air flow c. level the indoor coil's condensate pan to ensure proper drainage of condensate water d. make sure that the number of fins per inch of the new coils equals that of the replaced coils - Correct Answer-d (make sure that the number of fins per inch of the new coils equals that of the replaced coils)

Show more Read less
Institution
Course

Content preview

NATE Exam: Air Conditioning and Heat Pumps Newest Exam / NATE Air
Conditioning and Heat Pumps Preparation

NATE EXAM: AIR CONDITIONING AND HEAT PUMPS NEWEST EXAM / NATE AIR
CONDITIONING AND HEAT PUMPS PREPARATION/NATE AIR CONDITIONING AND
HEAT PUMPS EXAM PRACTICE EXAM WITH 150 QUESTIONS AND CORRECT
ANSWERS| BRAND NEW VERSION!
Why are more circuits needed in the outdoor coils used in heat pumps than in the
condenser coils used in cooling-only units?


a. To keep the pressure drop across the outdoor coil high
b. To keep the pressure drop across the outdoor coil low
c. To provide more subcooling during the cooling cycle
d. To provide more subcooling during the heating cycle - Correct Answer-b (To
keep the pressure drop across the outdoor coil low)


What is the typical water flow rate per ton of cooling for water-source heat pumps
operating in closed-loop systems?


a. 3.0 gpm per ton
b. 2.5 gpm per ton
c. 2.0 gpm per ton
d. 1.5 gpm per ton - Correct Answer-a (3.0 gpm per ton)


What tool should be used to shorten a capillary tube?




1|Page

, NATE Exam: Air Conditioning and Heat Pumps Newest Exam / NATE Air
Conditioning and Heat Pumps Preparation

a. A pair of pliers with side-cutter edges
b. A small tubing cutter
c. Any tubing cutter approved for use on refrigerant tubing
d. A triangular or knife-edge file - Correct Answer-d (A triangular or knife-edge file)


Which pressure in a TEV is the opening pressure?


a. Bulb pressure
b. Evaporator pressure
c. Spring pressure
d. A combination of bulb and spring pressures - Correct Answer-a (Bulb pressure)


What affect does a low refrigerant charge have on reversing valve operation?


a. It causes the slider to overheat
b. It creates a hissing sound in the reversing valve
c. It increases the chance that the reversing valve will not be able to transfer
properly
d. It has no effect on reversing valve operation - Correct Answer-c (It increases the
chance that the reversing valve will not be able to transfer properly)


When adding a heat pump to an existing fossil-fuel furnace, an installer must do
all of the following except ____.


2|Page

, NATE Exam: Air Conditioning and Heat Pumps Newest Exam / NATE Air
Conditioning and Heat Pumps Preparation



a. add a control to prevent the heat pump and furnace from operating at the same
time during normal heating
b. confirm there is adequate clearance around the outdoor section for good air
flow
c. level the indoor coil's condensate pan to ensure proper drainage of condensate
water
d. make sure that the number of fins per inch of the new coils equals that of the
replaced coils - Correct Answer-d (make sure that the number of fins per inch of
the new coils equals that of the replaced coils)


What is the purpose of a receiver?


a. It prevents liquid refrigerant from slugging the compressor
b. It removes heat from refrigerant vapor
c. It returns oil to the compressor at a rate the compressor can tolerate
d. It stores liquid refrigerant - Correct Answer-d (It stores liquid refrigerant)


What is the typical storage life of modern refrigerants?


a. 5 to 10 years
b. 10 to 20 years
c. 20 to 30 years



3|Page

, NATE Exam: Air Conditioning and Heat Pumps Newest Exam / NATE Air
Conditioning and Heat Pumps Preparation

d. Modern refrigerants have an indefinite storage life - Correct Answer-d (Modern
refrigerants have an indefinite storage life)


Which of the following should be used to leak-test refrigerant tubing?


a. Compressed air
b. Dry nitrogen
c. Oxygen
d. Water - Correct Answer-b (Dry nitrogen)


Of the motors commonly used in HVACR systems, which type has the lowest
starting torque?


a. PSC motor
b. Shaded-pole mole
c. Split-phase motor
d. Three-phase motor - Correct Answer-b (Shaded-pole motor)


What is the typical phase angle for a split-capacitor motor?


a. 15°
b. 30°
c. 75°

4|Page

Written for

Course

Document information

Uploaded on
October 13, 2025
Number of pages
37
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SophiaBennettRN Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
24
Member since
1 year
Number of followers
1
Documents
2322
Last sold
1 week ago
TopGrade Tutor: Expert Psychology, Nursing, Pharmacology & Computer and Math Resources

Welcome to my academic support store, your trusted destination for top-tier homework help and tutoring services! Specializing in key subjects like Psychology, Nursing, Human Resource Management, and Mathematics, I’m dedicated to helping students excel with high-quality, meticulously crafted resources. My mission is to deliver scholarly, reliable content that guarantees excellent grades, earning me a reputation as one of Stuvia’s BEST GOLD RATED TUTORS. Whether you need assistance with quizzes, exams, or detailed study materials, I prioritize your success with a commitment to academic excellence and results you can count on

Read more Read less
3.9

7 reviews

5
4
4
1
3
0
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions