Study online at https://quizlet.com/_hp2f6w
1. Building evacuation supervisor: 1 ) Who is responsible to report to the Fire Command Station in the
absence of a FLSD or a Deputy FLSD in an office building after normal business hours ? a ) floor warden b ) Chief
Engineer c ) Building Evacuation Supervisor d ) Fire Brigade member
2. Red: 2 ) If a building is equipped with a standpipe only , what color would the buildings fire department connection
be ? a ) red b ) green c ) yellow d ) silver
3. 30: 3 ) How many floor wardens are required in a 30 story Class B building ? a ) one b ) 30 c ) 60 d ) depends on
the square footage of each floor
4. Fixed Temperature heat detector: 4 ) Which of the following initiating devices must be replaced
after it has activated ? a ) rate of rise heat detector b ) single action pull station c ) carbon monoxide detector d ) fixed
temperature heat detector
5. S-14: 5 ) A technician enters your building to work on your buildings multizone standpipe system , as FLSD you
should ensure the technician possesses what certification ? ( Reference Material ) a ) 5-97 b ) w - 96 c ) S - 11 d ) S - 14
6. Some leakage from this valve is expected: 6 ) Water dripping from an automatic ball drip , after
the FDNY has disconnected from the FDNY connection , is an indication of a ) a defect in the FDNY Connection b ) some
leakage from this valve is expected c ) indicates a faulty lower check valve d ) indicates the system was overcharged
7. Surge signal: 7 ) All of the following are signals received at the Fire Alarm Control Panel except ? a ) alarm signa
b ) trouble signal c ) surge signal d ) supervisory signal
8. Manual pull station: 8 ) Which of the following will not cause a recall of a buildings elevators ? a ) smoke
detector in the elevator lobby b ) sprinkler activation c ) smoke detector in elevator machinery room d ) manual pull
station
9. Class B: 9 ) Under the 2014 building code , buildings that are used primarily for transacting business and
rendering professional services would be classified as___ ? a ) class J b ) class R - 1 c ) Class A d ) Class B
10. Roof relocation: 10 ) Which of the following is not an action to be taken during a fire or non fire emergency
? a ) shelter in place b ) in building relocation c ) partial evacuation d ) Roof relocation
11. 6: 11 ) If a building has 200 sprinkler heads in it's sprinkler system , how many spare heads must be kept on the
premises ? ( Reference Material ) a ) 6 b ) 12 c ) 24 d ) 10
12. Owner Representative: 12 ) All of the following are members of the Fire and Life Safety Staff except ? a
) Critical operations staff b ) Deputy Fire and Life Safety Director c ) Deputy Floor Warden d ) owner's representative
13. At the fire command center: 13 ) If a buildings auxiliary radio communication system is out of service
, a tag identifying the system as out if service must be placed at ? a ) the entrance to the building b ) at all warden
phone locations c ) at the Fire command center d ) at the building's communications center
, FLSD fire component quiz
Study online at https://quizlet.com/_hp2f6w
14. Jockey Pump: 14 ) Which of the following pumps is designed to operate when there is a slight drop in
pressure due to leakage or a pressure surge ? a ) Fire Pump b ) booster pump c ) special service pump d ) Jockey Pump
15. Riser: 15 ) The vertical portion of the system piping that delivers the water supply for hose connections and
sprinklers on standalone as well as combined systems is known as : a ) cross main b ) branch line c ) riser d ) feed main
16. Three hours: 16 ) The Fire Department recommends that the FLS staff participate in training designed to
familiarize them with their duties . The initial training in both fire and non - fire training the training duration for FLS
brigade members should be ( Both Parts ) ( Reference Material ) a ) two hours b ) three hours c ) one hour d ) thirty
minutes
17. Duct smoke detector: 17 ) Which of the following would result in the shutting down of a buildings HVAC
system ? a ) manual pull station b ) rate of rise heat detector c ) duct smoke detector d ) area smoke detector
18. On: 18 ) If the stem on an OS & Y valve is raised , this indicates a standpipe system is ? a ) on b ) out of service c
) off d ) defective
19. 40 Degrees: 19 ) The Temperature in the fire pump room should be kept at a minimum of . a ) 60 degrees b
) 40 degrees c ) 32 degrees d ) 50 degrees
20. Wet standpipe: 20 ) The most common standpipe system in operation is : a ) dry standpipe with automatic
dry pipe valve b ) wet standpipe c ) dry standpipe with no permanent water supply d ) yard system
21. donning a vest , armband , or other form of identification indicating their
role .: 1 ) Upon implementation of the FDNY plan or during the drills , the FLS Director must identify themselves to
building occupants and others by ? a ) standing at the fire command station . b ) donning a vest , armband , or other
form of identification indicating their role . c ) responding to the location of the reported emergency . d ) meeting the
fire department outside .
22. All of above: 2 ) In the event of a fire , a medical emergency or other non - fire emergency in the building
, the FLS Director must ? a . Always report to the fire command station . b . Implement such fire safety and / or non -
fire emergency actions as are warranted by the circumstances , in accordance with the provisions of the FDNY Plan , the
Fire Code , and the Fire Rules . . c Notify arriving emergency response personnel of the nature of the emergency and
the response thereto ; and d . Comply with the directions of the emergency response personnel and / or other lawful
authority . e . All of above
23. BES is allowed to perform FLS Director's duties in office buildings outside
regular business hours .: 3 ) Select the correct statement regarding Building Evacuation Supervisor ( BES
) . a . BES is authorized to perform FLS Director's duties when the FLS Director is out for lunch . b . BES is required to
possess a Certificate of Fitness . c . BES is allowed to perform FLS Director's duties in office buildings outside regular
business hours . d . BES is responsible to train FLS staff .
, FLSD fire component quiz
Study online at https://quizlet.com/_hp2f6w
24. The FLS Director must be fully familiar with the provisions of the FDNY
plan and must always conduct the FLS staff training and fire and non - fire
emergency drills required by Fire Code .: 4 ) Which of the following is incorrect concerning the
duties of the fire and life safety director ? a . The FLS Director must be fully familiar with the provisions of the FDNY
plan and must always conduct the FLS staff training and fire and non - fire emergency drills required by Fire Code . b .
The FLS Director must supervise and train the Deputy FLS Director and other FLS staff , including conducting initial and
periodic refresher training to maintain the state of readiness of such staff . c . The FLS Director must immediately report
to 911 any ( fire and non - fire ) emergency and any determination to implement the FDNY plan d . The FLS Director
must be responsible for a daily check of the availability of FLS wardens and Deputy FLS wardens ( if the wardens are
required in the premises ) , and make such notifications or temporary assignments as are necessary to ensure adequate
FLS staffing .
25. 1: 5 ) How many unwarranted unnecessary alarms are allowed to be transmitted in any three - month period before
the issuance of the fire department summons to the building ? a . 1 b.3 C.5 d.2
26. 45: 6 ) How many FLS Wardens are required in a 45 - story office building ? 4.1 b.20 C.44 d . 45
27. 3: 7 ) How many deputy FLS wardens are required in an open area office space of 22,500 sq / ft ? a.1 b.3 c.2 d.4
28. 911: 8 ) During a fire drill , occupants should be instructed to first notify in the event of a fire . a . the owner of
their company b . a family member c . the building manager d . 911
29. Report to the fire command station: 9 ) in the event of a fire , non - fire , or medical emergency ,
the on - duty FLS Director must ? a . Report the fire command station b . Evaluate reports from the floor wardens before
taking any action . c . Report the location of the emergency . d . Call the local firehouse and wait for their instructions .
30. At least one male and one female FLS searcher are required on each floor of
the building: 10 ) Fire and life safety searches are currently only required in the comprehensive fire safety and
emergency action plan for office buildings . Which of the following statements is incorrect about the searchers ? a .
At least one male and one female FLS searcher are required on each floor of the building b . FLS Searchers must be
on duty on each floor during regular business hours of such employers . c . in the absence of the deputy FLS warden
the searchers must perform the duties of the deputy FLS warden . d . The FLS searchers must assist the warden by
searching all areas floor to be relocated or evacuated .
31. Three: 11 ) Regarding initial training for fire and life safety staff members , the initial training for the FLS wardens
, deputy wardens , brigade members , and all other FLS staff in both fire safety and non - fire safety is how many hours
? ( Reference Material ) a . Five b . Six c . Three d . One
32. Call the FLS director immediately: 12 ) During regular business hours , in the event of a fire and /
or smoke condition or the activation of alarm the FLS Building Evacuation Supervisor must do all the following except