SOLAR FINAL QUESTIONS & ANSWERS

local authorities often supplement the NEC with special requirements called
__________________ - Answer -building ordinances

Article ___ of the NEC covers specific requirements unique to PV systems and
installations - Answer -690

The components that connect the PV source circuit to the rest of the system is the
_______________ - Answer -PV Output circuit

Inverter output circuit requirements are the same as _______ _______ residential wiring
requirements - Answer -General Purpose

The maximum voltage output of an array is properly calculated as the sum of the open-
circuit voltages of the series-connected modules with an adjustment for the __________
- Answer -temperature

The NEC identifies two types of PV circuit currents, _______________ current and PV
Output circuit current - Answer -PV source circuit

The maximum PV circuit output current is the value used to size circuit __________ and
circuit protection - Answer -Conductors

The maximum PV circuit current is equal to ____ of the sum of the individual source
circuit currents - Answer -125%

Typically, a PV system contains numerous strings of _______________ PV modules -
Answer -Series-connected

NEC requires the ________ of the conductors to be at least 125% of the maximum
current - Answer -ampacity

insufficient conductor size can cause inacceptable _______ losses - Answer -Voltage

__________ protects the conductor inside from unintended contact with personnel or
equipment - Answer -Insulation

PV output wiring is often the _______ run in a PV System - Answer -Longest

Conductor ampacity must be adjusted, or _______, according to the temperature -
Answer -De-Rated

A ______________ provides an alternative, low resistance emergency path for current
to flow and disperse into the earth - Answer -Grounding system

, in a 3-phase system, current flows through the _______ line only when there's an
imbalance - Answer -Neutral

NEC 690.48 requires the installation of a temporary _____________ to maintain ground
connection for safety while the system is being serviced - Answer -Bonding Jumper

A __________________ provides an electrical connection to earth - Answer -
Grounding Electrode

A __________ occurs when a short-circuit between either neutral or the powerlines and
ground occurs - Answer -Ground Fault

_________ strikes produce an enormous surge of current at high voltage - Answer -
Lighting

A _____________ network provides a low impedance path from the termination network
to the electrodes - Answer -Down Conductor

A _____________ responds to a sudden spike in voltage by shorting the lines to ground
to divert the surge to ground - Answer -Surge Arrestor

The ____ limits current to protect a system - Answer -TVSS

In PV systems, the surge arrestor on the DC side is located at the __________ -
Answer -Combiner Box

Since most PV work is outdoors, workers should protect themselves from solar radiation
by wearing a hat, safety glasses with ___________, and Sunscreen - Answer -UV
Protection

If a ladder will be near live electrical components, the hand rails of the ladder must be
made of non-conductive materials such as ___________ - Answer -Fiberglass

Some PV systems use batteries that contain ______________, which can cause
serious chemical burns - Answer -Corrosive Acids

A ______ circuit diagram uses a separate line to represent each conductor in an
electrical circuit - Answer -3-line

The most basic drawing that is used to represent the electrical flow of multiple wires
between components of an electrical system is a _____ circuit diagram - Answer -1-line

The _________ mounting style mounts the PV array in a permanent position - Answer -
Fixed Tilt

Geschreven voor

Instelling
Solar
Vak
Solar

Documentinformatie

Geüpload op
15 oktober 2025
Aantal pagina's
8
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
GEEKA YALA UNIVERSITY
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2101
Lid sinds
4 jaar
Aantal volgers
1446
Documenten
53792
Laatst verkocht
5 uur geleden

3.8

358 beoordelingen

5
177
4
61
3
48
2
17
1
55

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen