AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY
GRADED A+
Cracking of a coat is noted: - CORRECT ANSWERS-When the crack extends to the substrate
Checking can be Described as: - CORRECT ANSWERS-fine cracks in the surface of a coating
that don't extend through to the substrate
Adhesion Failures May be Caused by: - CORRECT ANSWERS-1. Contaminated surface 2.
Wrong surface prep. 3. Insufficient profile 4. Exceeding topcoat window
General types of holiday detectors include: - CORRECT ANSWERS-Low-voltage DC, High-
voltage DC, High-voltage AC
Low-voltage (wet sponge) holiday detectors are powered by batteries with output voltages ranging from
______. - CORRECT ANSWERS-5 - 120 V DC
What is a Standard? - CORRECT ANSWERS-An established norm or requirement that is written
by industry professionals.
A formal document that establishes uniform engineering or technical criteria, methods, processes and
practices
Surface temp must be _______ degrees greater than Dew Point in order to start coating. -
CORRECT ANSWERS-5 degrees
SSPC-PA2 - CORRECT ANSWERS-Procedure for determining conformance to Dry coating
thickness requirements.
ISO 8502.6 - CORRECT ANSWERS-Tests for the Assessment of Surface Cleanliness.
,ie. Bressel Patch, Salt Tests
ASTM - CORRECT ANSWERS-American Society for Testing and Materials
ISO - CORRECT ANSWERS-International Standard Organization
NACE (Nace International) - CORRECT ANSWERS-National Association of Corrosion Engineers
SSPC - CORRECT ANSWERS-Society for Protective Coatings
SSPC-SP15 - CORRECT ANSWERS-Commercial grade power tool cleaning
SSPC-SP16 - CORRECT ANSWERS-Brush-off blast cleaning of Non Ferrous Metals
SSPC-SP 14 - CORRECT ANSWERS-Industrial Blast Cleaning
10% Stain
SSPC-SP13 - CORRECT ANSWERS-Surface prep of concrete
SSPC-SP7 - CORRECT ANSWERS-Brush off blast cleaning
NACE SP0178 - CORRECT ANSWERS-Design, fabrication, and surface finish practices for tanks
and vessels to be lined for immersion service.
SSPC-SP 11 - CORRECT ANSWERS-Power Tool Cleaning to Bare Metal
SSPC-PA2 - CORRECT ANSWERS-Measurement of Dry Coat Thickness with magnetic gauges.
, SSPC-SP10/NACE 2 limits staining to ______per each unit area - CORRECT ANSWERS-5%
Near White Commercial Blast
SSPC-SP6/NACE 3 limits staining to _______per each unit area - CORRECT ANSWERS-33%
Commercial Blasts
NACE SP0188 - CORRECT ANSWERS-holiday testing
SSPC-SP1 - CORRECT ANSWERS-Solvent Cleaning
SSPC-SP5/NACE 1 limits staining to _________per each unit area - CORRECT ANSWERS-0%
White Metal Blast
2 Non-convertible coating types - CORRECT ANSWERS-1. Evaporation cure 2. Coalescence
cure
SSPC-VIS1 Defines surface covered with and rust as what grade? - CORRECT ANSWERS-Grade
B
SSPC-SP2
ISO St 3
ISO St 2
All deal with hand tool Cleaning. True or false? - CORRECT ANSWERS-True
Acrylic - CORRECT ANSWERS-A plastic resin that, when mixed with water and pigment, forms
an inorganic and quick-drying paint medium.
-Excellent UV and weather resistance