Harr Clinical Chemistry Exam Questions Save


with Verified Solutions


Terms in this set (620)


D. All of these options


D Absorbance is proportional to the inverse log of transmittance.
A = -log T = log 1/T
Which formula correctly Multiplying the numerator and denominator
describes the relationship by 100 gives:
between absorbance and %T ? A = log (100/100 X T) More

100 X T = %T,
A. A = 2 - log %T substituting %T for 100 X T gives:
B. A = log 1/T A = log 100/%T
C. A = -log T A = log 100 - log %T
D. All of these options A = 2.0 - log %T
For example, if %T = 10.0, then:
A = 2.0 - log 10.0
log 10.0 = 1.0
A = 2.0-1.0 = 1.0

A solution that has a B. 2.0
transmittance of 1.0 %T would
have an absorbance of: B
A = 2.0 - log %T
A. 1.0 A = 2.0 - log 1.0
B. 2.0 The log of 1.0 = 0
C. 1% A = 2.0
D. 99%

In absorption D. Absorbance is directly proportional to concentration
spectrophotometry:
D Beer's law states that A = a × b × c, where a is the absorptivity
A. Absorbance is directly coefficient (a constant), b is the path length, and c is
proportional to concentration. Absorbance is directly proportional to both b and
transmittance c. Doubling the path length results in incident light contacting
B. Percent transmittance is twice the number of molecules in solution. This causes
directly proportional to absorbance to double, the same effect as doubling the
concentration concentration of molecules.
C. Percent transmittance is
directly proportional to the light
path length
D. Absorbance is directly
proportional to concentration

,Which wavelength would be A. 450 nm
absorbed strongly by a red-
colored solution? A A solution transmits light corresponding in wavelength to its
color, and usually absorbs light of wavelengths complementary to
A. 450 nm its color. A red solution transmits light of 600-650 nm and strongly
B. 585 nm absorbs 400-500 nm light.
C. 600 nm
D. 650 nm

B. 525 nm
A green-colored solution would
show highest transmittance at:
B Green light consists of wavelengths from 500-550 nm. A green-
colored solution with a transmittance maximum of 525 nm and a
A. 475 nm
50-nm bandpass transmits light of 525 nm and absorbs light
B. 525 nm
below 475 nm and above 575 nm. A solution that is green would
C. 585 nm
be quantitated using a wavelength that it absorbs strongly, such as
D. 620 nm
450 nm.

SITUATION: A technologist is A. Replace the source lamp
performing an enzyme assay at
340 nm using a visible-range A Visible spectrophotometers are usually supplied with a tungsten
spectrophotometer. After setting or quartz halogen source lamp. Tungsten lamps produce a
the wavelength and adjusting the continuous range of wavelengths from about 320-2,000 nm.
readout to zero %T with the light Output increases as wavelength becomes longer peaking at
path blocked, a cuvette with around 1,000 nm, and is poor below 400 nm. As the lamp
deionized water is inserted. With envelope darkens with age, the amount of light reaching the
the light path fully open and the photodetector at 340 nm becomes insufficient to set the blank
100%T control at maximum, the reading to 100%T. Quartz halogen lamps produce light from 300
instrument readout will not rise nm through the infrared region. Deuterium or hydrogen lamps
above 90%T. What is the most produce ultraviolet-rich spectra optimal for ultraviolet (UV) work.
appropriate first course of Mercury vapor lamps produce a discontinuous spectrum that
action? includes a high output at around 365 nm that is useful for
fluorescent applications. Xenon lamps generate a continuous
A. Replace the source lamp spectrum of fairly uniform intensity from 300-2,000 nm, making
B. Insert a wider cuvette into the them useful for both visible and UV applications.
light path
C. Measure the voltage across
the lamp terminals
D. Replace the instrument fuse

, Which type of monochromator D. A prism and a variable exit slit
produces the purest
monochromatic light in the UV D Diffraction gratings and prisms both produce a continuous
range? range of wavelengths. A diffraction grating produces a uniform
separation of wavelengths. A prism produces much better
A. A diffraction grating and a separation of high-frequency light because refraction is greater
fixed exit slit for higher-energy wavelengths. Instruments using a prism and a
B. A sharp cutoff filter and a variable exit slit can produce UV light of a very narrow bandpass.
variable exit slit The adjustable slit is required in order to allow sufficient light to
C. Interference filters and a reach the detector to set 100%T.
variable exit slit
D. A prism and a variable exit slit

Which monochromator D. 5-nm bandpass
specification is required in order
to measure the true absorbance D Bandpass refers to the range of wavelengths passing through
of a compound having a natural the sample. The narrower the bandpass, the greater the
absorption bandwidth of 30 nm? photometric resolution. Bandpass can be made smaller by
reducing the width of the exit slit. Accurate absorbance
A. 50-nm bandpass measurements require a bandpass less than one-fifth the natural
B. 25-nm bandpass bandpass of the chromophore
C. 15-nm bandpass
D. 5-nm bandpass

D. Photomultiplier tube
Which photodetector is most
sensitive to low levels of light?
D The photomultiplier tube uses dynodes of increasing
voltage to amplify the current produced by the photosensitive
A. Barrier layer cell
cathode. It is 10,000 times as sensitive as a barrier layer cell, which
B. Photodiode
has no amplification. A photomultiplier tube requires a DC-
C. Diode array
regulated lamp because it responds to light fluctuations caused
D. Photomultiplier tube
by the AC cycle.

Which condition is a common C. Dispersion from second-order spectra
cause of stray light?
C Stray light is caused by the presence of any light other than the
A. Unstable source lamp voltage wavelength of measurement reaching the detector. It is most
B. Improper wavelength often caused by second-order spectra, deteriorated optics, light
calibration dispersed by a darkened lamp envelope, and extraneous room
C. Dispersion from second-order light.
spectra
D. Misaligned source lamp

Geschreven voor

Instelling
Earth System Science
Vak
Earth System Science

Documentinformatie

Geüpload op
21 oktober 2025
Aantal pagina's
29
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BrittieDonald Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
439
Lid sinds
2 jaar
Aantal volgers
162
Documenten
22045
Laatst verkocht
2 dagen geleden
BrittieDonald Study Solutions.

Get Help in Your Due Online and Actual Exams, Assignments with Well Researched and Up-to date Study Materials for Guaranteed Success

3.4

97 beoordelingen

5
43
4
14
3
7
2
5
1
28

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen