Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ABSA: 4th Class Part B - Comprehensive Exam 2 UPDATED ACTUAL QUESTIONS AND CORRECT ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
50
Cijfer
A+
Geüpload op
24-10-2025
Geschreven in
2025/2026

ABSA: 4th Class Part B - Comprehensive Exam 2 UPDATED ACTUAL QUESTIONS AND CORRECT ANSWERS What must be located outside a Class T machinery room? Select one: a. Spare flashlights b. Disposable coveralls c. Machinery shut off switch d. Light switches - Correct answersc Degradation of heat transfer fluid of a hot oil system will begin to occur if: Select one: a. The oil filter is not serviced regularly b. The oil temperature is above a specified range, for an extended period o

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

ABSA: 4th Class Part B - Comprehensive
Exam 2 UPDATED ACTUAL QUESTIONS
AND CORRECT ANSWERS
What must be located outside a Class T machinery room?

Select one:



a. Spare flashlights

b. Disposable coveralls

c. Machinery shut off switch

d. Light switches - Correct answers✔✔c



Degradation of heat transfer fluid of a hot oil system will begin to occur if:

Select one:



a. The oil filter is not serviced regularly

b. The oil temperature is above a specified range, for an extended period of time

c. The oil is allowed to churn in the circulating pump

d. The oil becomes too viscous - Correct answers✔✔b



Dry and flooded evaporators differ primarily in what respect?

Select one:



a. Dry evaporators use low-side floats, whereas flooded evaporators use high-side floats

b. Flooded systems primarily use Group B1 and B2 refrigerants

,c. The heat transfer surfaces of a flooded evaporator are kept covered with liquid refrigerant

d. The dry evaporator is designed to cool gases only - Correct answers✔✔c



It is good design practice to select a steam coil size so that:

Select one:



a. At least 10% of the coil capacity is needed when the air temperature at the coil inlet is €"5°C

b. At least 80% of the coil capacity is needed when the air temperature at the coil inlet is €"1°C

c. At least 40% of the coil capacity is needed when the air temperature entering the coil is €"1°C

d. 100% of the coil capacity is needed when the air temperature entering the coil is €"1°C -
Correct answers✔✔c



The final step when replacing a firetube is:

Select one:



a. Re-expansion

b. Hydrostatic test

c. Seal welding

d. Annealing the tube ends - Correct answers✔✔b



If a boiler sustains a low water condition

Select one:



a. open the safety valve or drum vent valve to release pressure.

b. use cool feedwater to quench any overheated heating surface.

,c. shut down the burner, let the boiler cool slowly, then drain and inspect it for damage due to
overheating.

d. immediately feed water into the boiler to raise the level. - Correct answers✔✔c



An advantage of a pump using a mechanical seal is:

Select one:



a. Ease of repair

b. Less lubrication

c. Less maintenance

d. Lower first cost - Correct answers✔✔c



For economical operation, the steam supply to a steam engine is cut off once the piston has
traveled _______ of its stroke.

Select one:



a. 1

b. 75% to 90%

c. 1/2 to 5/8

d. 1/4 to 1/3 - Correct answers✔✔d



A high stack temperature in a hot oil heater may indicate:

Select one:



a. Inadequate combustion air

b. A tube failure

, c. Excessive oil flow

d. Improper fuel-air ratio - Correct answers✔✔b



The type of pump normally used with a hot oil system is a:

Select one:



a. Sliding vane pump

b. Rotary screw pump

c. Conventional, single stage centrifugal pump

d. Multistage reciprocating pump - Correct answers✔✔c



Temperature relief devices can open on a rise in temperature by the expansion of a wax-filled rod
or by the:

Select one:



a. Action of a bellows

b. Action of a bi-metal strip

c. Melting of a fusible link

d. Melting of the alloy in a fusible plug - Correct answers✔✔d



Who should verify a steam boiler lockout?

Select one:



a. Each and every contractor or employee working on the boiler.

b. A representative of the plant Workplace Safety and Health committee.

Geschreven voor

Vak

Documentinformatie

Geüpload op
24 oktober 2025
Aantal pagina's
50
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
GENIOUSTOPCLASS
3.0
(1)

Maak kennis met de verkoper

Seller avatar
GENIOUSTOPCLASS Stanford
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
11 maanden
Aantal volgers
0
Documenten
1857
Laatst verkocht
7 maanden geleden
ACADEMIC EXAMS PLATFORM

I create high-quality, easy-to-understand academic documents to help students learn faster and perform better. My materials are well-researched, clearly organized, and cover key exam topics to make studying simple and effective.

3.0

1 beoordelingen

5
0
4
0
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen