Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Limited Scope of Radiography Practice Exam ACTUAL QUESTIONS AND CORRECT ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
14
Cijfer
A+
Geüpload op
30-10-2025
Geschreven in
2025/2026

Limited Scope of Radiography Practice Exam ACTUAL QUESTIONS AND CORRECT ANSWERS what statements are correct regarding the link between radiation and genetic effects - CORRECT ANSWER The link has been demonstrated in animal studies. Increased risk to humans cannot be predicted with respect to an individual. The changes in kilovoltage (kVp) will result in the greatest reduction of patient dose, when milliampere-seconds (mAs) is adjusted to compensate for the change - CORRECT ANSWER Increase kVp by 30% ______ _____ IR System speeds will result in the lowest patient dose - CORRECT ANSWER Faster speed IR system Infection control guidelines require: a. hand washing after contact w each patient b. destroying all contaminated linen c. sterilizing cassettes prior to use d. wearing gloves for all patient contact - CORRECT ANSWER contact w each patient a. hand washing after Which of the following sets of technical factors will produce the radiograph with the GREATEST DENSITY? a. 100 mA, 500 msec, 48" SID, 80 kVp b. 200 mA, 250 msec, 36" SID, 76 kVp c. 400 mA, 125 msec, 40" SID, 76 kVp d. 500 mA, 100 msec, 40" SID, 76 kVp - CORRECT ANSWER 36" SID, 76 kVp b. 200 mA, 250 msec, Grid cut-off on a radiograph may be caused by all of the following EXCEPT:

Meer zien Lees minder
Instelling
Limited Scope Of Radiography
Vak
Limited Scope of Radiography

Voorbeeld van de inhoud

Limited Scope of Radiography Practice
Exam ACTUAL QUESTIONS AND
CORRECT ANSWERS
what statements are correct regarding the link between radiation and genetic effects -
CORRECT ANSWER The link has been demonstrated in animal studies. Increased risk
to humans cannot be predicted with respect to an individual.



The changes in kilovoltage (kVp) will result in the greatest reduction of patient dose, when
milliampere-seconds (mAs) is adjusted to compensate for the change - CORRECT
ANSWER Increase kVp by 30%



______ _____ IR System speeds will result in the lowest patient dose - CORRECT
ANSWER Faster speed IR system



Infection control guidelines require:
a. hand washing after contact w each patient

b. destroying all contaminated linen

c. sterilizing cassettes prior to use

d. wearing gloves for all patient contact - CORRECT ANSWER a. hand washing after
contact w each patient



Which of the following sets of technical factors will produce the radiograph with the
GREATEST DENSITY?

a. 100 mA, 500 msec, 48" SID, 80 kVp

b. 200 mA, 250 msec, 36" SID, 76 kVp

c. 400 mA, 125 msec, 40" SID, 76 kVp

d. 500 mA, 100 msec, 40" SID, 76 kVp - CORRECT ANSWER b. 200 mA, 250 msec,
36" SID, 76 kVp


Grid cut-off on a radiograph may be caused by all of the following EXCEPT:

, a. a tube that is off-center

b. a tube that is angled perpendicular to the lead strips

c. grid motion being started before the exposure is made

d. improper distance being used with a focused grid - CORRECT ANSWER c. grid
motion being started before the exposure is made


The purpose of the x-ray tube housing is to:

1. provide adequate filtration

2. provide electrical shielding

3. control leakage radiation - CORRECT ANSWER 2 & 3 only



The primary purpose of using gonad shields is to: - CORRECT ANSWER reduce the
likelihood of genetic effects



There are two types of gonad shielding: - CORRECT ANSWER Contact and shadow



Gonad shielding should be used when the gonads are within ____ cm of the _________
______. - CORRECT ANSWER when the gonads are within 5 cm of the radiation field



the greatest cause of unnecessary radiation to patients that can be controlled by the limited
operator is _____ ________ - CORRECT ANSWER repeat exposures



The limited operator can reduce repeat exposure by: - CORRECT ANSWER clearly
instructing patients


The x-ray beam restriction minimizes patient exposure because it _____ the radiation to the
___ __ ______. - CORRECT ANSWER it limits the radiation field to the area of
interest


What is the device that allows the limited operator to vary the size of the radiation field? -
CORRECT ANSWER collimator

Geschreven voor

Instelling
Limited Scope of Radiography
Vak
Limited Scope of Radiography

Documentinformatie

Geüpload op
30 oktober 2025
Aantal pagina's
14
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STANFORDTOPGRADES Stanford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
53
Lid sinds
1 jaar
Aantal volgers
2
Documenten
6927
Laatst verkocht
9 uur geleden
TOPSELLER

Hi there! I'm dedicated to sharing my high-quality study guides and helpful EXAM Materials to make your learning easier and more efficient. All my materials are well-organized and tailored to help you ace your courses. I offer genuine and dependable exam papers that are directly obtained from well-known, reputable institutions as a highly regarded professional who specializes in sourcing study materials. Kindly don't hesitate to contact me, my study guides, notes and exams or test banks, are 100% graded and fully guaranteed

Lees meer Lees minder
3.9

7 beoordelingen

5
3
4
1
3
2
2
1
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen