EPA 608 (TYPE II) Exam Questions with correct Answers /. When a new system has been assembled, the first thing to do is? - Answer-Pressurize the system with an inert gas & leak check. /.After installation of a field-piped R-410A split heat pulp, the unit should first be? - Answer-Pressurized with nitrogen then leak checked. /.The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds _________ of the charge per year? - Answer-15% /.R-410A requires recovery tanks rated for at least? - Answer-400 psig /.After refrigerant liquid has been recovered from a system, any remaining vapor is? - Answer-Condensed by the recovery system. /.Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover refrigerant from a unit with R-22. What must be done before the R-22 refrigerant can be recovered/recycled? - Answer-Recover as much R-502 from the recovery unit as possible, change filter, & evacuate. /.In a refrigeration system with a TXV (or other type of throttling device), the component directly following the condenser is the? - Answer-Receiver /.When charging an R-410A system that uses a water-cooled condenser, you must first charge with vapor to a pressure of at least________, before switching to liquid charging. - Answer-120 psig /.Recovered refrigerant may contain what? - Answer-1.) Acids 2.) Moisture 3.) Oils /.Your recovery/recycling machine has R-22 refrigerant in it. You now have to recover refrigerant from a unit with R-410A. What must be done before your recovery unit can be used to recover R-410A? - Answer-1.) The recovery unit must be EPA certified for use with R-410A. 2.) The recovery tank must be designed for the pressure of R-410A. 3.) The filter & lubricant in the recovery unit must be changed, & the recovery unit evacuated. /.To recover liquid refrigerant, you must connect one hose to the? - Answer-Liquid Line. /.The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove the charge from the cylinder as a? - Answer-Liquid /.Before using a recovery unit to remove a charge, what steps should be taken? - Answer-1.) Check service valve positions. 2.) Check the oil level in the recovery unit. 3.) Evacuate recovery unit & recovery tank. /.On refrigeration units that use an open compressor; the ________ is most likely to leak if the unit is not used for several months. - Answer-The rotating shaft seal. /.Noncondensables in a system cause? - Answer-Higher discharge pressure. /.Heat Pumps that use R-410A should be leak checked with? - Answer-Pressurized Nitrogen. /.A reciprocating compressor should not be energized when? - Answer-The discharge service valve is closed. /.In a refrigeration system, the component directly following the evaporator is the? - Answer-Accumulator. /.Manifold gauge set hoses should have self-sealing connectors or hand valves to? - Answer-Minimize the release of refrigerant when the hoses are connected & disconnected. /.The EPA regulations require that leaking commercial or industrial process refrigeration equipment must be repaired when the leak rate exceeds _____ of the charge per year. - Answer-35% /.Moisture is removed from a system by? - Answer-Using a filter drier. /.Oil foaming usually occurs in the? - Answer-Compressor

Show more Read less
Institution
EPA 608
Course
EPA 608

Content preview

EPA 608 (TYPE II) Exam Questions with correct
Answers

/. When a new system has been assembled, the first thing to do is? - Answer-
✅Pressurize the system with an inert gas & leak check.

/.After installation of a field-piped R-410A split heat pulp, the unit should first be? -
Answer-✅Pressurized with nitrogen then leak checked.

/.The EPA regulations require that any appliances containing more than 50 pounds of
refrigerant (except for commercial & industrial process refrigeration) must be repaired
when the leak rate exceeds _________ of the charge per year? - Answer-✅15%

/.R-410A requires recovery tanks rated for at least? - Answer-✅400 psig

/.After refrigerant liquid has been recovered from a system, any remaining vapor is? -
Answer-✅Condensed by the recovery system.

/.Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover
refrigerant from a unit with R-22. What must be done before the R-22 refrigerant can be
recovered/recycled? - Answer-✅Recover as much R-502 from the recovery unit as
possible, change filter, & evacuate.

/.In a refrigeration system with a TXV (or other type of throttling device), the component
directly following the condenser is the? - Answer-✅Receiver

/.When charging an R-410A system that uses a water-cooled condenser, you must first
charge with vapor to a pressure of at least________, before switching to liquid charging.
- Answer-✅120 psig

/.Recovered refrigerant may contain what? - Answer-✅1.) Acids

2.) Moisture

3.) Oils

/.Your recovery/recycling machine has R-22 refrigerant in it. You now have to recover
refrigerant from a unit with R-410A. What must be done before your recovery unit can
be used to recover R-410A? - Answer-✅1.) The recovery unit must be EPA certified for
use with R-410A.

, 2.) The recovery tank must be designed for the pressure of R-410A.

3.) The filter & lubricant in the recovery unit must be changed, & the recovery unit
evacuated.

/.To recover liquid refrigerant, you must connect one hose to the? - Answer-✅Liquid
Line.

/.The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is
to use a remove the charge from the cylinder as a? - Answer-✅Liquid

/.Before using a recovery unit to remove a charge, what steps should be taken? -
Answer-✅1.) Check service valve positions.

2.) Check the oil level in the recovery unit.

3.) Evacuate recovery unit & recovery tank.

/.On refrigeration units that use an open compressor; the ________ is most likely to leak
if the unit is not used for several months. - Answer-✅The rotating shaft seal.

/.Noncondensables in a system cause? - Answer-✅Higher discharge pressure.

/.Heat Pumps that use R-410A should be leak checked with? - Answer-✅Pressurized
Nitrogen.

/.A reciprocating compressor should not be energized when? - Answer-✅The discharge
service valve is closed.

/.In a refrigeration system, the component directly following the evaporator is the? -
Answer-✅Accumulator.

/.Manifold gauge set hoses should have self-sealing connectors or hand valves to? -
Answer-✅Minimize the release of refrigerant when the hoses are connected &
disconnected.

/.The EPA regulations require that leaking commercial or industrial process refrigeration
equipment must be repaired when the leak rate exceeds _____ of the charge per year. -
Answer-✅35%

/.Moisture is removed from a system by? - Answer-✅Using a filter drier.

/.Oil foaming usually occurs in the? - Answer-✅Compressor

Written for

Institution
EPA 608
Course
EPA 608

Document information

Uploaded on
November 1, 2025
Number of pages
6
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainariam Harvard University
Follow You need to be logged in order to follow users or courses
Sold
148
Member since
1 year
Number of followers
7
Documents
8376
Last sold
1 week ago

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Read more Read less
3.3

25 reviews

5
8
4
2
3
8
2
3
1
4

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions