Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

STATE OF OHIO FIRE ALARM TEST PRACTICE CORRECT 100%

Beoordeling
-
Verkocht
-
Pagina's
14
Cijfer
A+
Geüpload op
03-11-2025
Geschreven in
2025/2026

Smoke detectors for door release services shall be: - ANSWERphotoelectric type ionization other approved type The number of supervisory devices permitted to be connected to a single initiating device circuit shall not exceed _____ - ANSWERFifteen True or False The fire marshal must approve a presignal system - ANSWERTrue

Meer zien Lees minder
Instelling
OHIO FIRE ALARM
Vak
OHIO FIRE ALARM

Voorbeeld van de inhoud

STATE OF OHIO FIRE ALARM TEST
PRACTICE CORRECT 100%
Smoke detectors for door release services shall be: - ANSWERphotoelectric type
ionization
other approved type

The number of supervisory devices permitted to be connected
to a single initiating device circuit shall not exceed

_____ - ANSWERFifteen

True or False
The fire marshal must approve a presignal system - ANSWERTrue

Power limited fire alarm cable shall have a voltage rating of _____
Volts? - ANSWER30V

What type of fire alarm system transmits alarms to a public fire
service? - ANSWERmunicipal fire alarm system

Wall mounted audible notification appliances shall have their
tops above finished floor at heights of not less than __ inches
and below the finished ceilings at distances not to exceed
inches - ANSWER90,6

When manual fire alarm boxes are used, the distance between
boxes will not be in excess of - ANSWER200ft

A signaling method characterized by simultaneous or
sequential transmission or both, and reception of multiple
signals in a transmission channel including means for positively
identifying each signal is - ANSWERmultiplexing

All - ANSWERAir duct detectors shall be installed in such a way as to obtain a
representative sample of the air stream. This installation shall be
permitted to be achieved by any of the following methods:

rigid mounting within the duct

rigid mounting to the wall of the duct with the sensing element protruding into the duct

outside the duct with rigidly mounted sampling tubesprotruding into the duct

, through the duct with projected light beam

All

Smoke detectors shall be spaced within ___ feet of the peak
measured horizontally - ANSWER3

The minimum decibel level for fire alarm signal is ___ ? - ANSWER75db

Visible notification appliances shall be installed within _ feet
of the end of the corridor with a separation of no greater than
_____ feet - ANSWER15,100

True or False

It is permissible for the fire alarm system to share a circuit with
the exit lights - ANSWERFalse

NFPA standard 72E suggests using what method to test heat
detectors - ANSWERhair dryer

Manual fire alarm boxes shall be ___ in color. - ANSWERred

Actuation of alarm notification appliances or emergency voice
communications, fire alarm safety functions, and annunciation at
the protected premises shall occur within
activation of the initiating device - ANSWER10

True or False

In one or two family dwelling units a smoke detector shall be
placed on each level, including the basement - ANSWERTrue

All smoke detectors receiving the annual testing shall be tested
by what means - ANSWERsmoke and aerosol not harmful to man

True or False

Pneumatic line type detectors shall be tested for leaks and
proper operation at six-month intervals - ANSWERFalse

True or False
Mirrors are allowed to be installed in projected beam detectors - ANSWERTrue

True or false
Optical cables are permitted in fire alarm wiring - ANSWERTrue

Geschreven voor

Instelling
OHIO FIRE ALARM
Vak
OHIO FIRE ALARM

Documentinformatie

Geüpload op
3 november 2025
Aantal pagina's
14
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
shantelleG West Virgina University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
640
Lid sinds
3 jaar
Aantal volgers
369
Documenten
18239
Laatst verkocht
1 dag geleden
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.0

118 beoordelingen

5
69
4
11
3
24
2
2
1
12

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen