Septic License Exam Version 1 Newest 2025/2026
Complete All 100 Questions And Correct Detailed
Answers (Verified Answers) |Already Graded
A+||Brand New Version!!
What are the capacities for each side of a septic tank? -
.....ANSWER ...✔✔ 2/3 inlet side, 1/3 outlet side
How many inches lower should the outlet be from the
inlet in a septic tank? - .....ANSWER ...✔✔ 3"
What information must be present on the outlet side of
a septic tank? - .....ANSWER ...✔✔ - Name of
manufacturer
- Date manufactured
- Size of tank in gallons
- External load limit
- Warning placard
How many additional gallons per bedroom are required
for each bedroom beyond 3? - .....ANSWER ...✔✔ 125
gallons
, 2|Page
How many additional gallons per bedroom are required
for each bedroom beyond 4? - .....ANSWER ...✔✔ 225
gallons
How far below finished grade can clean out and baffle
inspection manholes be? - .....ANSWER ...✔✔ No
deeper than 12"
Tank riser covers shall be at least _________ lbs,
or_______________________, or
_______________________________ - .....ANSWER ...✔✔ 59
lbs, tank covers shall remain on tank clean outs, a
secondary safety device shall be provided
What are the 3 main functions of a septic tank? -
.....ANSWER ...✔✔ 1. Removes most of the settleable
solids
2. Provides and effluent of relatively uniform physical,
chemical and biological characteristics
3. Provides some reduction in pollution levels in the
effluent
Where should perc tests be conducted? - .....ANSWER
...✔✔ In primary and reserve septic areas