EXAM WITH QUESTIONS AND WELL
VERIFIED ANSWERS|| ALREADY GRADED A+ ||
GUARANTEED PASS || LATEST UPDATE 2025
What is the minimum distance a power vent can be from a lot line for a furnace
(fuel burning appliance ) ?
A. 6 '
B. 12 '
C. 10 '
D. 9 ' - ANSWER-C. 10 '
In the single- and two - family dwelling code , holes bored or cut into joists ,
rafters , or beams shall not be closer than _____ inches to the top or bottom of
the member.
A. 1/2
B. 2
C. 1 1/2
D. 1 - ANSWER-B. 2
In a halfway house (Group R-4), what class ceiling finish is permitted ?
A. Both a Class A and a Class C finish
B. Both a Class B and a Class C finish
C. Only a Class B finish
,D. Either a Class A or Class B finish - ANSWER-D. Either a Class A or Class
B finish
What is the maximum length of exit access travel permitted in occupancies
which contain materials that are highly toxic health hazards (H-4) , in feet ?
A. 75
B. 100
C. 150
D. 175 - ANSWER-D. 175
Accessible dressing rooms must have a minimum floor area of 5'-0" by 6'-0".
What is the minimum required diameter of the clear floor area at 12" above the
floor ?
A. 44 "
B. 48 "
C. 54 "
D. 60 " - ANSWER-D. 60 "
OSHA requires the top height of top rails used in guard rail systems is to be :
A. 36 inches to 42 inches
B. 36 inches to 48 inches
C. 42 inches , plus or minus 3 inches
D. 42 inches to 48 inches - ANSWER-C. 42 inches , plus or minus 3 inches
The weight of which one of the following is considered not to be a dead load ?
A. Partition walls not connected to the ceiling
B. Partition walls connected to the ceiling
C. Snow
D. Stairways - ANSWER-C. Snow
,A 4 x 4 concrete pad is placed on dense gravel . What is the net allowable
bearing pressure the soil will be able to support from a load placed on that pad ,
in tons.
A. 32
B. 48
C. 64
D. 96 - ANSWER-D. 96
The maximum moisture content for fire retardant treated wood structural panels
is ____.
A. 28 %
B. 23 %
C. 19 %
D. 15 % - ANSWER-D. 15 %
Which of the following is NOT required on a commercial building permit
application ?
A. Building owner's or authorized agent's signature
B. Description of land where proposed work is to be done
C. Proposed building occupancy use group
D. Projected date for beginning construction - ANSWER-D. Projected date for
beginning construction
When installing asphalt shingles on the roof of a detached single – family
dwelling , what is the minimum pitch permissible ?
A. 2
B. 3
C. 4
, D. 5 - ANSWER-A. 2
What is a kip ?
A. a chase for HVAC ducts
B. an insulation permeability factor
C. a structural steel deflection ratio
D. one thousand pounds - ANSWER-D. one thousand pounds
Timber footings are to be treated unless _______.
A. Placed on bedrock
B. Subjected to a constant water table
C. Support type V construction
D. Placed entirely below the permanent fresh water line - ANSWER-D. Placed
entirely below the permanent fresh water line
In which use group are six townhouse units , side by side , three stories and less
?
A. R - 1
B. R - 3
C. R - 4
D. A - 2 - ANSWER-B. R - 3
Self supporting extra-heavy-duty type IA metal portable ladders must support at
least _______ times the maximum intended load.
A. 4.5
B. 3.6
C. 3.3