Test Prep (GCS) Questions And
Quality Verified Answers
Who is responsible for requiring the wearing of appropriate personal protective equipment?
REFERENCE: OSHA - 1926.28(a) - Correct Answer The employer
Valley flashing for metal roof shingles shall extend at least:
REFERENCE: FBC-B 2020/2017 - 1507.5.7 - Correct Answer 8 inches from the centerline each
way
How many plies of coal tar built-membrane are needed to waterproof a wall when the
hydrostatic pressure is 49 feet?
REFERENCE: NRCA-2020-WATERPROOF-PG.43 & 44 - Correct Answer 3
On counter flashing systems, flashing receivers should be:
REFERENCE: SMACNA-PG.4.6 - Correct Answer 16 oz. copper
A roofing crew should be able to place ___ squares per day of mechanically fastened EPDM
roofing.
REFERENCE: WALKERS 31ST - PG.825 - Correct Answer 35
,In batten seam roofing, the recommended MAXIMUM distance between battens is:
REFERENCE: SMACNA-(7th)-PG. 6.18 - Correct Answer 20 inches
In a HVHZ, no re-cover applications shall take place over which of the following existing
materials?
REFERENCE: FBC-B 2020/2017 - 1521.16 - Correct Answer Wood shingles
It is recommended that drip edge metal for tile roof systems be fabricated from:
REFERENCE: NRCA Steep Slope (2021) PG. 226 - Correct Answer 16 oz copper
A gallon of water weighs:
REFERENCE: NRCA-2020-WATERPROOFING - PG. 30 - Correct Answer 62.4 lbs per cubic foot
What is the nominal weight of 22-gage stainless steel?
REFERENCE: SMACNA-(7th) - PG. A.3 - TABLE A-4 - Correct Answer 1.31 lb. /ft2
On a sloping roof penetration extend the flashing flange a minimum of:
REFERENCE: SMACNA-(7th) -PG. 8.24 - Correct Answer 4 inches onto the roof
, Special Kraft-faced fiberglass batts come in two thicknesses and are:
REFERENCE: RCE-PG. 350 - Correct Answer 24 inches wide and 48 inches long
Per NRCA, skylight frames should overlap the curb a minimum of how many inches to act as a
counterflashing or a separate counterflashing should be installed?
REFERENCE: NRCA-METAL PANEL AND SPF - PG. 153 and PG. 165 (2016) and PG. 201 and PG.
440 (2020) - Correct Answer 3 inches
Per NRCA, which of the following is not a bitumen used for built-up membrane systems (BUR)?
REFERENCE: NRCA-2019-MEMBRANE-PG. 174 - Correct Answer Coal-tar system
According to Walker's, when performed metal siding is laid on roofs, it should have an end lap
of:
REFERENCE: WALKERS-(31st) - PG. 811 - Correct Answer 3 to 6 inches depending on the pitch
of the roof.
Horizontal grade roof cements are used for embedding metal flashing flanges and forming seals
at:
REFERENCE: NRCA MEMBRANE 2019 PG. 194 - Correct Answer Penetrations
What is the MINIMUM design slope for liquid-applied roofs according to the Florida Building
Code?