EXAM 2025-2026 WITH 180 PREP
QUESTIONS AND VERIFIED CORRECT
ANSWERS | ALREADY GRADED A+ |
GUARANTEED PASS | CONSTRUCTION
SUPERVISOR LICENSE LATEST EXAM 2025-
2026
Light transmitting plastic glazing of unprotected openings shall not be installed
more than ______ feet above mean grade in an un - sprinkled building.
A. 30
B. 50
C. 75
D. 90 - ANSWER-C. 75
Wood structural panels with a rating of 32/16 have a maximum span of 16 inches
when used as:
A. roof sheathing
B. floor sheathing for floors without wood strip flooring
,C. floor sheathing for parquet floors
D. roof, floor, or wall sheathing - ANSWER-B. floor sheathing for floors without
wood strip flooring
What is the smallest area required for a habitable room, except kitchens?
A. 120 square feet
B. 100 square feet
C. 96 square feet
D. 70 square feet - ANSWER-D. 70 square feet
In a sprinkled, 60 ' x 80 ' building without corridors, where two exit doors are
required they must be placed not less than ______ feet apart
A. 25
B. 33-1/3
C. 40
D. 50 - ANSWER-B. 33-1/3
The minimum uniformly distributed live load for handrails around a balcony on a
motel is _______ lbs . per linear foot.
A. 300
B. 200
C. 100
D. 50 - ANSWER-D. 50
The bottom of footings must be stepped if they have a slope in excess of ________
percent.
A5
,B. 10
C. 8
D. 12 - ANSWER-B. 10
Buildings constructed of gypsum board panel and fiberboard panel sheathed cold-
formed steel light - frame construction are limited to a maximum height of _____
feet
A. 48
B. 42
C. 35
D. 30 - ANSWER-C. 35
Concrete slabs directly on ground in an industrial park shall have a minimum
thickness of:
A. 3 inches with an approved vapor barrier
B. 4 inches without an approved vapor barrier
C. 3½ inches with or without an approved vapor barrier
D. 5 inches on a stone base without an approved vapor barrier - ANSWER-C. 3½
inches with or without an approved vapor barrier
What is the maximum floor area allowed per occupant for standing room in an
assembly use group , such as an exhibition hall ?
A One person per 5 ft.²
B. One person per 7 ft.²
C. One person per 15 ft.²
D. One person per 20 ft.² - ANSWER-A One person per 5 ft.²
, What is the minimum water resistant barrier to be attached to the sheathing on an
exterior wall?
A. one layer of 15 pound asphalt felt
B. one layer of six mil polyvinyl chloride
C. one layer of 30 pound asphalt felt
D. Tyvek Home Wrap - ANSWER-A. one layer of 15 pound asphalt felt
Wood entirely and continuously below the groundwater level supporting
permanent structures__________.
A. must be naturally durable
B. must be preservative-treated
C. is not required to be preservative-treated
D. is not permitted - ANSWER-C. is not required to be preservative-treated
Four percent of the _______ is the minimum openable area to the outdoors that is
required for natural ventilation of the room or space being ventilated.
A. total gross building area
B. floor areas of a room minus wall openings
C. floor area of the room
D. wall openings and floor areas of a room - ANSWER-C. floor area of the room
You are about to begin the construction of an attached single car garage . The
building official may require you to notify him of such before the start of work.
A. seven business days
B. one business day
C. 48 hours