What is the fuel classification for combustible metals?
A. Class A
B. Class B
C. Class C
D. Class D - Correct Answer > Class D
In regards to carbon dioxide fire-extinguishing systems, total flooding systems are
designed to deliver at least ___ percent concentration of CO into and enclosed
area.
A. 21
B. 19
C. 34
D. 15 - Correct Answer > 34
True or False, NFPA 72 allows only manual pull stations and water flow detection
devices to be used on shunt systems. Fire detection devices are not permitted. -
Correct Answer > True
,Fire detection and alarm systems are designed to the requirements found in NFPA
____ , National Fire Alarm Code.
A. 72
B. 82
C. 13R
D. 1001 - Correct Answer > 72
Which of the following main views of plans and specifications are found on
working drawings?
A. Plan
B. Elevation
C. Sectional
D. Detailed
E. All the above - Correct Answer > All the above
Which of the following are a type of sprinkler?
A) ESFR
B) EC
C) AF
D) A and B - Correct Answer > A and B
Foam water system design and installation requirements are regulated by
___________.
A. NFPA 13
,B. NFPA 13R
C. NFPA 25
D. NFPA 16 - Correct Answer > NFPA 16
The fire alarm control panel (FACP) is essentially the _____ of the system. - Correct
Answer > Brain
Heat sensing fire detector color coding has a RED extra high temperature rating
of?
A.) 0-99f
B.)175-249f
C.) 325-399f
D.) 500-575f - Correct Answer > 325-399f
According to NFPA, travel distances to a manual pull station should not exceed
_____ feet.
A. 100
B. 200
C. 300
D. 400 - Correct Answer > 200
What color tag is used to indicate that an alarm system is impaired?
A. White
B. Yellow
, C. Blue
D. Red - Correct Answer > Red
About _____ % of fire deaths are attributed to smoke inhalation and not to burns.
A. 55%
B. 60%
C. 65%
D. 70% - Correct Answer > 65%
When performing maintenance inspections of occupancies with alarm systems,
the first step will be to:
A) Check for green light indicating normal operation
B) Confirm monitoring status with alarm company
C) Confirm panel is locked and inaccessible to public
D) Confirm system has been tested by licensed alarm contractor and has a current
inspection tag - Correct Answer > Confirm system has been tested by licensed alarm
contractor and has a current inspection tag
Most people are well aware of the dangers of fire but less aware of the dangers of
smoke inhalation. About ___% of of fire deaths are attributed to smoke inhalation
and not to burns.
A) 65
B) 80
C) 92
D) 75 - Correct Answer > 65