Test STUDY GUIDE 2026 COMPLETE
QUESTIONS WITH CORRECT DETAILED
ANSWERS || 100% GUARANTEED PASS
<RECENT VERSION>
1. The setting of a car governor electrical contact on cars 500 foot a minute or
less must be below what percentage less then the car governor tripping speed
- ANSWER ✔ 10%
2. The mechanical tripping speed of the governor cannot be lower than what
percentage of the car speed - ANSWER ✔ 115%
3. Which of the following is the most important part of any job in an elevator
industry - ANSWER ✔ Safety procedures
4. What function does a starter panel perform - ANSWER ✔ Starting the MG
set
5. What could be the cause of an intermittent loop overload trip - ANSWER ✔
Brake not lifting, properly the car is overloaded,excessive motor bearing
friction
,6. What is the purpose of a relay Armature residual guard - ANSWER ✔
Prevents relay from failing to drop due to residual magnetism
7. What is the result of too large of a relay Armature airgap - ANSWER ✔
Positive pick up may be lost
8. How is a magnetic blowout coil wired in relation to the circuit it's contact
controls - ANSWER ✔ Series
9. What should be observed before performing maintenance on a really logic
controller - ANSWER ✔ Have replacement parts available, protect the area
below your work area, lock and tag out the mainline
10.What is the purpose of options-isolators On solid state controllers -
ANSWER ✔ To interface high and low voltage
11.What is the maximum soldering iron wattage for use on printed circuit
boards - ANSWER ✔ 40w
12.The frequency of maintenance operation and the exact procedures vary by
manufacture and the duty of the equipment. - ANSWER ✔ True
13.Following the proper _______ procedures should be practiced on a _______
basis - ANSWER ✔ safety, daily
, 14.Wear safety glasses at all times. - ANSWER ✔ True
15.Every job should be equipped with an approved _______, _______,
_______ and _______. - ANSWER ✔ First aid kit, MSDS, emergency
phone numbers, type ABC Fire extinguisher
16.Follow your companies approved _______ procedure. - ANSWER ✔ Lock
out Tag out
17.The approved method of troubleshooting an energized circuit has a meter
lead permanently attached to a reference and the other lead probing the
circuitry. - ANSWER ✔ True
18.You can replace a fuse with a higher current capacity fuse. - ANSWER ✔
False
19._______ to building personnel that you are working on the jobsite and a
general scope of _______ you will perform. - ANSWER ✔ Communicate,
work
20.Leave keys in the car station that control the operation of the elevator. -
ANSWER ✔ False
21.Protect work areas from _______ and _______ and reduce tripping hazards.
- ANSWER ✔ grease, oil