EPA 608 (TYPE II) Exam ACTUAL QUESTIONS AND CORRECT ANSWERS When a new system has been assembled, the first thing to do is? - CORRECT ANSWERSPressurize the system with an inert gas & leak check. After installation of a field-piped R-410A split heat pulp, the unit should first be? - CORRECT ANSWERSPressurized with nitrogen then leak checked. The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds _________ of the charge per year? - CORRECT ANSWERS15% R-410A requires recovery tanks rated for at least? - CORRECT ANSWERS400 psig After refrigerant liquid has been recovered from a system, any remaining vapor is? - CORRECT ANSWERSCondensed by the recovery system. Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover refrigerant from a unit with R-22. What must be done before the R-22 refrigerant can be recovered/recycled? - CORRECT ANSWERSRecover as much R-502 from the recover

Show more Read less
Institution
Course

Content preview

EPA 608 (TYPE II) Exam ACTUAL
QUESTIONS AND CORRECT ANSWERS
When a new system has been assembled, the first thing to do is? - CORRECT
ANSWERS✅✅Pressurize the system with an inert gas & leak check.


After installation of a field-piped R-410A split heat pulp, the unit should first be? -
CORRECT ANSWERS✅✅Pressurized with nitrogen then leak checked.


The EPA regulations require that any appliances containing more than 50 pounds of
refrigerant (except for commercial & industrial process refrigeration) must be repaired when
the leak rate exceeds _________ of the charge per year? - CORRECT ANSWERS✅✅15%



R-410A requires recovery tanks rated for at least? - CORRECT ANSWERS✅✅400 psig


After refrigerant liquid has been recovered from a system, any remaining vapor is? -
CORRECT ANSWERS✅✅Condensed by the recovery system.


Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover
refrigerant from a unit with R-22. What must be done before the R-22 refrigerant can be
recovered/recycled? - CORRECT ANSWERS✅✅Recover as much R-502 from the recovery
unit as possible, change filter, & evacuate.


In a refrigeration system with a TXV (or other type of throttling device), the component
directly following the condenser is the? - CORRECT ANSWERS✅✅Receiver


When charging an R-410A system that uses a water-cooled condenser, you must first charge
with vapor to a pressure of at least________, before switching to liquid charging. -
CORRECT ANSWERS✅✅120 psig



Recovered refrigerant may contain what? - CORRECT ANSWERS✅✅1.) Acids


2.) Moisture

, 3.) Oils


Your recovery/recycling machine has R-22 refrigerant in it. You now have to recover
refrigerant from a unit with R-410A. What must be done before your recovery unit can be
used to recover R-410A? - CORRECT ANSWERS✅✅1.) The recovery unit must be EPA
certified for use with R-410A.


2.) The recovery tank must be designed for the pressure of R-410A.


3.) The filter & lubricant in the recovery unit must be changed, & the recovery unit
evacuated.


To recover liquid refrigerant, you must connect one hose to the? - CORRECT
ANSWERS✅✅Liquid Line.


The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a
remove the charge from the cylinder as a? - CORRECT ANSWERS✅✅Liquid


Before using a recovery unit to remove a charge, what steps should be taken? - CORRECT
ANSWERS✅✅1.) Check service valve positions.


2.) Check the oil level in the recovery unit.


3.) Evacuate recovery unit & recovery tank.


On refrigeration units that use an open compressor; the ________ is most likely to leak if the
unit is not used for several months. - CORRECT ANSWERS✅✅The rotating shaft seal.



Noncondensables in a system cause? - CORRECT ANSWERS✅✅Higher discharge
pressure.

Written for

Course

Document information

Uploaded on
November 10, 2025
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$9.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
GENIOUSTOPCLASS
3.0
(1)

Get to know the seller

Seller avatar
GENIOUSTOPCLASS Stanford
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
11 months
Number of followers
0
Documents
1857
Last sold
7 months ago
ACADEMIC EXAMS PLATFORM

I create high-quality, easy-to-understand academic documents to help students learn faster and perform better. My materials are well-researched, clearly organized, and cover key exam topics to make studying simple and effective.

3.0

1 reviews

5
0
4
0
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions