ARMY ESQD
PRINCIPLES
What is the maximum amount of net explosive weight (NEW) you can
store in this potential explosion site (PES)?
PES: AGS (L) HD 1.4
D=30 ft
PES: AGS (L) HD 1.4 - ANSWERS->0 lb<
3,000 lbs
500,000 lbs
What is the minimum separation distance between this potential
explosion site (PES) and exposed site (ES)?
PES: Explosives loading pier HD 1.1 NEW=1,000,000 lbs
ES: operating building - ANSWERS->600 ft<
1,100 ft
1,800 ft
4,000 ft
END OF
PAGE
1
, APPLICATION OF US LATEST
ARMY ESQD
PRINCIPLES
What is the maximum amount of net explosive weight (NEW) you can
store in this potential explosion site (PES)?
PES: operating building HD 1.1
D=3,000 ft
ES: Explosives loading pier - ANSWERS->200,000 lbs<
300,000 lbs
500,000 lbs
700,000 lbs
What is the maximum separation distance between these two
unbarricaded combat aircraft parking area (CAPA)?
U CAPA HD 1.1 NEW=3,000 lbs
U CAPA HD 1.1 NEW=3,000 lbs - ANSWERS-130 ft
139 ft
>159 ft<
188 ft
END OF
PAGE
2
, APPLICATION OF US LATEST
ARMY ESQD
PRINCIPLES
What is the maximum amount of net explosive weight (NEW) you can
store in this potential explosion site (PES)?
ES: AE cargo area HD 1.3
D=200 ft
PES: Recreation area; no structure - ANSWERS->20,000 lbs<
30,000 lbs
50,000 lbs
70,000 lbs
The DA PAM 385-64 contains the minimum required ESQD criteria for
- ANSWERS-all branches of service
the Air Force
>the Army<
the Navy
END OF
PAGE
3