STATIONARY ENGINEER EXAM BUNDLE DEAL
High pressure steam boilers generally operate at
pressures
A. above 15 psi and over 6 boiler horsepower.
B. below 15 psi and over 8 boiler horsepower.
C. above 250 psi and over 6 boiler horsepower.
D. at 212 psi and over 8 boiler horsepower. -
.....ANSWER... ✔✔ A. above 15 psi and over 6 boiler
horsepower.
Pressure gauges should never have a range less than
A. half the safety valve set pressure.
B. double the safety valve set pressure.
C. 3/4 times the safety valve set pressure.
D. 1 1/2 times the safety valve set pressure. -
.....ANSWER... ✔✔ D. 1 1/2 times the safety valve
set pressure.
After water is blown out of a siphon, why should live
steam never be allowed to enter a Bourdon tube?
A. The steam will rupture the siphon tube.
,2|Page
B. Combustion gases will mix with the steam.
C. Live steam will damage the pressure gauge.
D. The water level gauge will be damaged or
destroyed. - .....ANSWER... ✔✔ C. Live steam will
damage the pressure gauge.
All of the following are essential to maintain the proper
fuel oil pressure with fuel oil accessories EXCEPT
A. achieving the right flow of fuel.
B. proper atomization of the fuel oil.
C. heating fuel oil to the correct temperature.
D. obtaining the correct difference in pressure inside and
outside the boiler. - .....ANSWER... ✔✔ D. obtaining
the correct difference in pressure inside and outside the
boiler.
Which of the following could be dangerous to safe
operation of a low pressure boiler?
A. Adding water to an operating boiler when the water
level cannot be seen in the gauge glass tube.
B. Opening the blowdown valve at the bottom of the
water gauge glass before making a water level
reading.
,3|Page
C. Checking the water level using the try cocks valves
when the line to the glass gauge tube is clogged.
D. Opening the water column blowdown valve every
day. - .....ANSWER... ✔✔ A. Adding water to an
operating boiler when the water level cannot be seen in
the gauge glass tube.
Which of the following is best if a low-pressure boiler
does not have an air vent?
A. Vent the boiler with the try cocks.
B. Vent the boiler with the safety valve.
C. Vent the boiler with the fusible plug.
D. Vent the boiler with the blowdown line. -
.....ANSWER... ✔✔ A. Vent the boiler with the try
cocks.
What is the purpose of an evaporation test on a low
pressure boiler?
A. To test the water column
B. To test the bottom blowdown valve
C. To test the steam pressure safety valve
D. To test the low water cutoff control. - .....ANSWER...
✔✔ D. To test the low water cutoff control.
, 4|Page
Following flame failure, controls must de-energize fuel
and ignition circuits
A. within 4 seconds.
B. within 6 seconds.
C. within 10 seconds.
D. within 15 seconds. - .....ANSWER... ✔✔ A. within 4
seconds.
How can an operator prevent damage to the tubes
while using a cleaner to remove scale from boiler tubes?
A. Never use a chemical cleaning procedure.
B. Never use cleaning water under pressure.
C. Never allow the cleaner to stay in one place.
D. Never clean the tubes more often than every six
months. - .....ANSWER... ✔✔ C. Never allow the
cleaner to stay in one place.
In a steam boiler, which of the following should never be
placed between the safety relief valve and the boiler?
A. A steam trap
B. A shut-off valve
C. An air eliminator