A colorless, odorless, electrically nonconductive inert gas
that is a suitable medium for extinguishing Class B and
Class C fires - ....ANSWER ....✔✔ Carbon Dioxide
A powder composed of very small particles, usually
sodium bicarbonate, potassium bicarbonate, or
ammonium phosphate-based with added particulate
material supplemented by special treatment toprovide
resistance to packing, resistance to moisture absorption
(caking), and the proper flow capabilities - ....ANSWER
....✔✔ Dry Chemical
Normally an aqueous solution of organic or inorganic
salts or a combination thereof that forms an
extinguishing agent. - ....ANSWER ....✔✔ Wet
chemical
,2|Page
Electrically non-conducting, volatile, or gaseous fire
extinguishant that does not leave a residue
uponevaporation. - ....ANSWER ....✔✔ Clean Agent
A system that is constructed in a manner that does not
introduce foreign material into the agent being
recovered and has a means of visually inspecting the
recovered agent for contaminants. - ....ANSWER
....✔✔ Dry Chemical Closed Recovery System
A system that provides for the transfer of halogenated
agents between fire extinguishers, supply containers,
and recharge and recovery containers so that none of
the halogenated agent escapes to the atmosphere. -
....ANSWER ....✔✔ Halogenated Closed Recovery
System
Cylinders (and cartridges) containing nitrogen,
compressed air, carbon dioxide, or other gases at a
pressure higher than 500 psi (3447 kPa) at 70°F
(21°C). - ....ANSWER ....✔✔ High-Pressure Cylinder
Cylinders containing fire extinguishing agent (medium),
nitrogen, compressed air, or other compressed gases at
a service pressure of 500 psi (3447 kPa) or lower at
,3|Page
70°F (21°C). - ....ANSWER ....✔✔ Low-Pressure
Cylinder
Solid materials in powder or granular form designed to
extinguish Class D combustible metal fires by crusting,
smothering, or heat-transferring means. - ....ANSWER
....✔✔ Dry Powder
Either a local alarm device to indicate when an
extinguisher is removed from its designated location or
a method of electronic communication (data transmission)
between an in-place fire extinguisher and an electronic
monitoring device/system. - ....ANSWER ....✔✔
Electronic Monitoring
Extinguisher retention device designed to mount and
secure a specific extinguisher model onto various
surfaces by incorporating releasable straps or bands to
secure the fire extinguisher. - ....ANSWER ....✔✔
Extinguisher Bracket
An identifiable and readily accessible fire extinguisher
housing device designed to store and protect fire
equipment. - ....ANSWER ....✔✔ Extinguisher Cabinet
, 4|Page
Extinguisher mounting device designed for mounting a
specific extinguisher model onto stationary vertical
surfaces. - ....ANSWER ....✔✔ Extinguisher Hanger
A quick check that a fire extinguisher is in its designated
place, that it has not been actuated or tampered with,
and that there is no obvious physical damage or
condition to prevent its operation. - ....ANSWER
....✔✔ Extinguisher Inspection
A thorough examination of the fire extinguisher that is
intended to give maximum assurance that a fire
extinguisher will operate effectively and safelyand to
determine if physical damage or condition will prevent
its operation, if any repair or replacement is necessary,
and if hydrostatic testing or internal maintenance is
required. - ....ANSWER ....✔✔ Extinguisher
Maintenance
A solution that will form an aqueous film on liquid fuels -
....ANSWER ....✔✔ Film-Forming Foam
A solution based on fluorinated surfactants plus foam
stabilizers to produce a fluid aqueous film for