1. when tanks arrive at the job site, how should they be
unloaded? - ...ANSWER...✓✓ lifted off with a cable
attached to the tank lifting lugs
As an alternative lifting method, should a cable or chain
be wrapped around the tank? - ...ANSWER...✓✓ No,
Never!
When you are lifting a tank, using the lifting lugs, which of
these procedures should be followed? - ...ANSWER...✓✓
attach a triangle cable through the lugs with no more
than a 30 degree angle from the center line.
After you unload a new tank on a clean level surface at
the job site what else should you do prior to inspection
and pre-testing? - ...ANSWER...✓✓ Chock the tank to
prevent it from Rolling
,2|Page
which of the following items should be physically checked
for damage or imperfections at the job site? -
...ANSWER...✓✓ Piping (steel and fiberglass)
Fittings, Vents, Fillboxes, anodes, ECT..
The tanks themselves
(ALL OF THE ABOVE)!
STI-P3 tanks are delivered with shipping plugs in tank
openings. What should be done to these plugs prior to
testing? - ...ANSWER...✓✓ remove the plugs and replace
them with a standard threaded plug that is properly
doped
should dielectric bushings be installed in all openings of
an STI-P3 tank? - ...ANSWER...✓✓ yes on all openings
what is the maximum air pressure to which a steel tank
should be subjected in a pre-installation test? -
...ANSWER...✓✓ 5 pounds
for fiberglass reinforced plastic (FRP) tanks up to 12 feet
in diameter what is an acceptable air pressure to which
,3|Page
the tanks may be subjected in a pre-installation test? -
...ANSWER...✓✓ 3 pounds
for FRP tanks over 12 feet in diameter what is the
maximum air pressure to which the tanks should be
subjected in a pre-installation test? - ...ANSWER...✓✓ 3
pounds
when you are conducting an air test on a tank the type of
gauge that should be used is? - ...ANSWER...✓✓ a
pressure gauge with a maximum limit of 10 to 15 PSIG
the proper procedure for conducting a pre-installation air
test of a steel tank is to? - ...ANSWER...✓✓ apply 3 to 5
pounds of pressure and soap all surfaces and weld
seams visible through the coating while inspecting for
bubbles.
what is the proper procedure for conducting a pre-
installation air test of an FRP tank Under 12 feet in
diameter is to.... - ...ANSWER...✓✓ apply 3 pounds of air
pressure and soap all surfaces while inspecting for any
sign of a leak either audible or visible in the form of
bubbles on the surface
, 4|Page
a double-walled steel tank build in accordance with UL
standard 58 is? - ...ANSWER...✓✓ requires air testing of
the interstitial space prior to installation
the proper procedure for conducting a pre-installation air
test of a double-walled tank is to? - ...ANSWER...✓✓
pressurize the inner tank monitor the pressure for one
hour and then pressurize the space between the inner
and outer tanks with the air from the inner tank
when shipped a steel tank is covered with a coating that
is an important part of the tanks Corrosion Prevention
system. "holidays" which show up in the coating at the
installation site should? - ...ANSWER...✓✓ should be
touched up with a compatible coating after proper surface
preparation
touch up of holidays in a steel tank coatings at the
installation site should be done....... - ...ANSWER...✓✓
according to the manufacturer's instructions
dielectric bushings are usually made of what? -