Content preview

ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION/ ICC CALIFORNIA UST SERVICE TECHNICIAN
CERTIFICATION EXAM PREPARATION ACTUAL EXAM

Which agency approves a site-specific variance which allows for an alternative method of construction or
monitoring:

a.) The Regional Water Quality Board

b.) The State Water Resources Control Board

c.) The Department of Toxic Substance Control

d.) The local agency - (answer) a.) The Regional Water Quality Board

CCR Title 23, Sec 2681(a)



The regulations to enforce compliance of underground storage tank systems in the state are found in?

a.) Code of Federal Regulations, 40 CFR Part 281

b.) California Code of Regulations, Title 23, Chapter 16

c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17 - (answer) b.) California Code of Regulations;
Title 23, Chapter 16



By definition an "underground storage tank system" includes

a.) The tank, all connected piping and dispensers

b.) The tank, all connected piping, ancillary equipment and containment system

c.) Only the tank

d.) Only tanks totally beneath the surface of the ground - (answer) b.) The tank, all connected piping,
ancillary equipment and containment system



(H&SC, Sec 25281(z))



The written report submitted to the local agency after an unauthorized release is required to include the
following except:

a.) Description of actions taken to stop the release

b.) Cause of the release

c.) Method of disposal of released product

,ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION/ ICC CALIFORNIA UST SERVICE TECHNICIAN
CERTIFICATION EXAM PREPARATION ACTUAL EXAM

d.) Date on which the release was discovered - (answer) b.) Cause of the release

CCR Title 23, Sec 2652(c)



An unauthorized release which does not escape from secondary containment only requires a record on
the operator's monitoring reports provided:

A. It did not increase the hazard of fire

B. It did not cause any deterioration of the secondary containment

C. It was cleaned up within 8 hours of detection

D. All of the above - (answer) D. All of the above

H&SC, Sec 25294



The annual monitoring certification may be performed by:

A. A person possessing the appropriate contractors licenses

B. An individual trained and certified by the manufacturer of the monitoring equipment

C. A designated UST operator

D. A person who meets the requirements of both a and b - (answer) D. A person who meets the
requirements of both a and b

CCR Title 23, Sec 2715(i)



When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate a post-
test hard copy data report of the following information, except:

a.) Liquid volume

b.) Fuel depth

c.) Outside air temperature

d.) Time and date of test - (answer) c.) Outside air temperature

CCR Title 23, Sec 2643(b)(1)



If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert the transfer operator
when the tank is no more than ___________ full

,ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION/ ICC CALIFORNIA UST SERVICE TECHNICIAN
CERTIFICATION EXAM PREPARATION ACTUAL EXAM

a.) 85%

b.) 95%

c.) 90%

d.) 80% - (answer) c.) 90%



An automatic tank gauge is utilized for leak detection of the ______________.

a.) Tank

b.) Tank and Piping

c.) Piping

d.) Interstitial space - (answer) a.) Tank

CCR Title 23, Sec 2643(b)(1)



After completion of enhanced leak detection (ELD) test, the ELD test results must be submitted to the
_________________.

a.) The local agency

b.) The SWRCB

c.) Owner of the UST system

d.) To both the SWRCB and the local agency - (answer) d.) To both the SWRCB and the local agency

CCR Title 23, Sec 2644.1(a)(5)



A permit to operate a UST system must have all of the following listed on the permit, EXCEPT:

a.) The state UST identification number(s)

b.) Name of the tank manufacturer and tank capacity

c.) Permit expiration date

d.) Monitoring requirements - (answer) b.) Name of the tank manufacturer and tank capacity

CCR Title 23, Sec 2712(c)



A temporary closure is appropriate for which of the following:

, ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION/ ICC CALIFORNIA UST SERVICE TECHNICIAN
CERTIFICATION EXAM PREPARATION ACTUAL EXAM

a.) The UST system is empty and will be removed from service indefinitely

b.) The UST system has ceased to store hazardous materials but will be used within the next 12
consecutive months

c.) The UST system is unable to meet compliance requirements and will be removed

d.) The UST system has been red-tagged - (answer) b.) The UST system has ceased to store hazardous
materials but will be used within the next 12 consecutive months

CCR Title 23, Sec 2671 & 2670



A local agency determines that a UST facility within the last year had compliance issues. Prior to issuing
a new permit or renewal to operate an UST the local agency shall:

a.) Ask the state to assist in a joint inspection

b.) Request the owner/operator to submit a "Return to Compliance" form.

c.) Refer to a District Attorney Investigator

d.) Inspect the facility and determine compliance - (answer) d.) Inspect the facility and determine
compliance

CCR Title 23, Sec 2712(c)



All the following components require third party certification, except:

a.) Automatic tank gauging systems

b.) Statistical inventory reconciliation methods

c.) Spill Containment lids

d.) Liquid phase out-of-tank products - (answer) c.) Spill Containment lids



The exterior surface of an underground storage tank must bear a marking or label which shows the
following information, except:

a.) Design pressure in psig

b.) Useable capacity in gallons.

c.) Width of the interstitial space

d.) Identity of manufacturer - (answer) c.) Width of the interstitial space

Written for

Institution
ICC CALIFORNIA UST
Course
ICC CALIFORNIA UST

Document information

Uploaded on
November 17, 2025
Number of pages
136
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$17.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StudyGiant Walden University
Follow You need to be logged in order to follow users or courses
Sold
7476
Member since
1 year
Number of followers
7
Documents
3392
Last sold
3 days ago

4.3

70 reviews

5
49
4
6
3
6
2
2
1
7

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions