Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ASSE 6005 Certification Questions with Answers Verified 100% Correct

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
19-11-2025
Geschreven in
2025/2026

ASSE 6005 Certification Questions with Answers Verified 100% Correct Source Valve - ANSWER -Shutoff valve at immediate connection of each source to piped distribution system Cryogenic Fluid - ANSWER -A fluid with a boiling point lower than -130 deg F at an absolute pressure of 14.7 psi Main Line Valve - ANSWER -Shutoff valve in main supply line inside of the building 200 psi - ANSWER -Instrument air design pressure Riser Valve - ANSWER -Shutoff valve in each riser adjacent to main line Service Valve - ANSWER -Shutoff valve in each lateral branch from main or riser Zone Valve - ANSWER -Shutoff valves for station outlets and inlets In-line Valve - ANSWER -Shutoff valves for servicing individual rooms or areas Diameter Index Safety System - ANSWER -D.I.S.S. Pin Index - ANSWER -Medaes/Ohmeda/Ohio Latch Type - ANSWER -Chemetron Geometric Type - ANSWER -Puritan Bennett Quick Connect - ANSWER -Schrader Primary Valve - ANSWER -Allows user to disconnect equipment without causing leakage Secondary Valve - ANSWER -Allows for removal of front assembly for maintenance and repair without leakage by automatically closing to stop flow of gas 24 hours - ANSWER -Standing pressure test length National Institute of Standards and Technology - ANSWER -NIST 23.5% - ANSWER -Oxygen concentration by volume for an oxygen enriched atmosphere CGA E-10 - ANSWER -CGA Standard to establish a maintenance program at a facility 72 in^2 - ANSWER -Minimum free area for louvered openings for natural ventilation Demand Check Fitting - ANSWER -Used to facilitate service, testing, or replacement of all pressure switches and mainline gauges downstream of the source valve 21 CFR 210 and 21 CFR 211 - ANSWER -FDA Current Good Manufacturing Practices for bulk liquid oxygen 20 ft - ANSWER -Height above ground for medical air intakes 36 in - ANSWER -Minimum backfilled cover for buried piping 18 in - ANSWER -Minimum backfilled cover for buried piping where physical damage is otherwise prevented ASME Section IX - ANSWER -Brazing procedures and brazer performance shall be qualified in accordance with ______ 1000 - ANSWER -Melting temperature for brazing alloys BCuP series - ANSWER -Filler metal for copper-to-copper joints 80 psi - ANSWER -Pressure where outlets need to be either D.I.S.S. Or designed to relief pressure before removal of adapter 20 ft - ANSWER -Maximal interval for pipe labels 1000 psi - ANSWER -Minimum burst pressure for flex hose and connectors ASTM B88, ASTM B819, ASTM B280, Stainless Steel - ANSWER -Pipe types for medical-surgical vacuum systems Oxygen Analyzer - ANSWER -Used to assure all ambient air has been removed from the pipeline prior to brazing Specific Name - ANSWER -Indicated on continuous tape or marker to identify buried pipeline 150 psi - ANSWER -Minimum test pressure for initial pressure test Schedule 40 - ANSWER -Minimum wall thickness for Category 3 vacuum system with plastic piping ASTM B819 - ANSWER -Hard-drawn, seamless copper tube for Category 3 positive pressure gases Brass, Bronze, Stainless Steel - ANSWER -Allowable pressure relief valve materials

Meer zien Lees minder
Instelling
ASSE 6005 Certification
Vak
ASSE 6005 Certification

Voorbeeld van de inhoud

ASSE 6005 Certification Questions with Answers
Verified 100% Correct
Source Valve - ANSWER -Shutoff valve at immediate connection of each source
to piped distribution system

Cryogenic Fluid - ANSWER -A fluid with a boiling point lower than -130 deg F
at an absolute pressure of 14.7 psi

Main Line Valve - ANSWER -Shutoff valve in main supply line inside of the
building

200 psi - ANSWER -Instrument air design pressure

Riser Valve - ANSWER -Shutoff valve in each riser adjacent to main line

Service Valve - ANSWER -Shutoff valve in each lateral branch from main or
riser

Zone Valve - ANSWER -Shutoff valves for station outlets and inlets

In-line Valve - ANSWER -Shutoff valves for servicing individual rooms or areas

Diameter Index Safety System - ANSWER -D.I.S.S.

Pin Index - ANSWER -Medaes/Ohmeda/Ohio

Latch Type - ANSWER -Chemetron

Geometric Type - ANSWER -Puritan Bennett

Quick Connect - ANSWER -Schrader

, Primary Valve - ANSWER -Allows user to disconnect equipment without causing
leakage

Secondary Valve - ANSWER -Allows for removal of front assembly for
maintenance and repair without leakage by automatically closing to stop flow of
gas

24 hours - ANSWER -Standing pressure test length

National Institute of Standards and Technology - ANSWER -NIST

23.5% - ANSWER -Oxygen concentration by volume for an oxygen enriched
atmosphere

CGA E-10 - ANSWER -CGA Standard to establish a maintenance program at a
facility

72 in^2 - ANSWER -Minimum free area for louvered openings for natural
ventilation

Demand Check Fitting - ANSWER -Used to facilitate service, testing, or
replacement of all pressure switches and mainline gauges downstream of the
source valve

21 CFR 210 and 21 CFR 211 - ANSWER -FDA Current Good Manufacturing
Practices for bulk liquid oxygen

20 ft - ANSWER -Height above ground for medical air intakes

36 in - ANSWER -Minimum backfilled cover for buried piping

18 in - ANSWER -Minimum backfilled cover for buried piping where physical
damage is otherwise prevented

Geschreven voor

Instelling
ASSE 6005 Certification
Vak
ASSE 6005 Certification

Documentinformatie

Geüpload op
19 november 2025
Aantal pagina's
5
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TheExamMaestro Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
144
Lid sinds
2 jaar
Aantal volgers
5
Documenten
3369
Laatst verkocht
2 dagen geleden
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.6

18 beoordelingen

5
9
4
2
3
2
2
0
1
5

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen