ASSE 6005 Certification Questions with Answers Verified 100% Correct 23.5% - ANSWER -Oxygen concentration by volume for an oxygen enriched atmosphere CGA E-10 - ANSWER -CGA Standard to establish a maintenance program at a facility 72 in^2 - ANSWER -Minimum free area for louvered openings for natural ventilation Demand Check Fitting - ANSWER -Used to facilitate service, testing, or replacement of all pressure switches and mainline gauges downstream of the source valve 21 CFR 210 and 21 CFR 211 - ANSWER -FDA Current Good Manufacturing Practices for bulk liquid oxygen 20 ft - ANSWER -Height above ground for medical air intakes 36 in - ANSWER -Minimum backfilled cover for buried piping 18 in - ANSWER -Minimum backfilled cover for buried piping where physical damage is otherwise prevented ASME Section IX - ANSWER -Brazing procedures and brazer performance shall be qualified in accordance with ______ 1000 - ANSWER -Melting temperature for brazing alloys BCuP series - ANSWER -Filler metal for copper-to-copper joints 80 psi - ANSWER -Pressure where outlets need to be either D.I.S.S. Or designed to relief pressure before removal of adapter 20 ft - ANSWER -Maximal interval for pipe labels 1000 psi - ANSWER -Minimum burst pressure for flex hose and connectors ASTM B88, ASTM B819, ASTM B280, Stainless Steel - ANSWER -Pipe types for medical-surgical vacuum systems Oxygen Analyzer - ANSWER -Used to assure all ambient air has been removed from the pipeline prior to brazing Specific Name - ANSWER -Indicated on continuous tape or marker to identify buried pipeline 150 psi - ANSWER -Minimum test pressure for initial pressure test Schedule 40 - ANSWER -Minimum wall thickness for Category 3 vacuum system with plastic piping ASTM B819 - ANSWER -Hard-drawn, seamless copper tube for Category 3 positive pressure gases Brass, Bronze, Stainless Steel - ANSWER -Allowable pressure relief valve materials Category 1 - ANSWER -Likely to cause major inury or death of patient or caregiver Category 2 - ANSWER -Likely to cause minor injury to patient or caregiver Category 3 - ANSWER -Not likely to cause injury, but may cause patient discomfort Category 4 - ANSWER -No impact on patient care Area Alarm System - ANSWER -Within an area of use, provides continuous audible and visible surveillance of Level 1 and 2 systems Local Alarm System - ANSWER -Provides continuous audible and visible surveillance of system source equipment at equipment site Master Alarm System - ANSWER -Monitors operation and condition of the source of supply, the reserve source (if any), and the pressure in the main lines of each system Critical Care Areas - ANSWER -Special care units, intensive care units, coronary care units, angiography laboratories, cardiac catheterization laboratories, delivery rooms, emergency departments, and similar areas in which patients are intended to be subjected to invasive procedures and connected to line-operated, patient care related electrical devices ASSE 6005 - ANSWER -Medical Gas Systems Generalist ASSE 6010 - ANSWER -Medical Gas Systems Installer ASSE 6015 - ANSWER -Bulk Medical Gas Systems Installer ASSE 6020 - ANSWER -Medical Gas Systems Inspector ASSE 6030 - ANSWER -Medical Gas Systems Verifier ASSE 6035 - ANSWER -Bulk Medical Gas Systems Verifier ASSE 6040 - ANSWER -Medical Gas Systems Maintenance Personnel ASSE 6050 - ANSWER -Medical Gas Systems Instructor ASSE 6055 - ANSWER -Bulk Medical Gas Systems Instructor

Meer zien Lees minder
Instelling
ASSE 6005 Certification
Vak
ASSE 6005 Certification

Voorbeeld van de inhoud

ASSE 6005 Certification Questions with Answers
Verified 100% Correct

23.5% - ANSWER -Oxygen concentration by volume for an oxygen enriched
atmosphere

CGA E-10 - ANSWER -CGA Standard to establish a maintenance program at a
facility

72 in^2 - ANSWER -Minimum free area for louvered openings for natural
ventilation

Demand Check Fitting - ANSWER -Used to facilitate service, testing, or
replacement of all pressure switches and mainline gauges downstream of the
source valve

21 CFR 210 and 21 CFR 211 - ANSWER -FDA Current Good Manufacturing
Practices for bulk liquid oxygen

20 ft - ANSWER -Height above ground for medical air intakes

36 in - ANSWER -Minimum backfilled cover for buried piping

18 in - ANSWER -Minimum backfilled cover for buried piping where physical
damage is otherwise prevented

ASME Section IX - ANSWER -Brazing procedures and brazer performance shall
be qualified in accordance with ______

1000 - ANSWER -Melting temperature for brazing alloys

BCuP series - ANSWER -Filler metal for copper-to-copper joints

, 80 psi - ANSWER -Pressure where outlets need to be either D.I.S.S. Or designed
to relief pressure before removal of adapter

20 ft - ANSWER -Maximal interval for pipe labels

1000 psi - ANSWER -Minimum burst pressure for flex hose and connectors

ASTM B88, ASTM B819, ASTM B280, Stainless Steel - ANSWER -Pipe types
for medical-surgical vacuum systems

Oxygen Analyzer - ANSWER -Used to assure all ambient air has been removed
from the pipeline prior to brazing

Specific Name - ANSWER -Indicated on continuous tape or marker to identify
buried pipeline

150 psi - ANSWER -Minimum test pressure for initial pressure test

Schedule 40 - ANSWER -Minimum wall thickness for Category 3 vacuum
system with plastic piping

ASTM B819 - ANSWER -Hard-drawn, seamless copper tube for Category 3
positive pressure gases

Brass, Bronze, Stainless Steel - ANSWER -Allowable pressure relief valve
materials
Category 1 - ANSWER -Likely to cause major inury or death of patient or
caregiver

Category 2 - ANSWER -Likely to cause minor injury to patient or caregiver

Category 3 - ANSWER -Not likely to cause injury, but may cause patient
discomfort

Geschreven voor

Instelling
ASSE 6005 Certification
Vak
ASSE 6005 Certification

Documentinformatie

Geüpload op
19 november 2025
Aantal pagina's
5
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TopGradeGuru Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
15
Lid sinds
1 jaar
Aantal volgers
0
Documenten
2399
Laatst verkocht
4 weken geleden
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it\'s the go-to resource for exam preparation and academic success.

1.5

2 beoordelingen

5
0
4
0
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen