What is the minimum space between ground rods? - Answer Six feet
What color triangle marking will be on a noise cancelling outlet? - Answer Orange
Fraud, deceit, or willful violation of the electrical administrative act may incur of a fine of.... -
Answer Not more than $10,000
An electrical contractor doesn't need a permit for.... - Answer Minor work $100 or less
A master must be _ to qualify for the electrical examination - Answer 22 years of age and
12,000 hours
A journeyman must be _ of experience - Answer 20 years of age and 8,000 hours
Bonding to a pool grid has to have what type of devices - Answer Pressure devices
Convenience outlets must be GFCI and located between _ and _ of the inside of the wall of a
pool - Answer 6ft and 20ft
Type RTRC shall be permitted to be unsupported where the raceway is not more than __ long
and remains in unbroken lengths and terminated in an outlet box - Answer 3 feet
Receptacle outlets shall be installed so that no point along the wall line of a kitchen countertop
is more than _ inches measured horizontally from a receptacle outlet in that space - Answer
24 inches
What is the minimum size THW conductor that can be used to supply a 200A single phase
commercial building - Answer 3/0 copper
, What is the expansion rate of 250 feet of pvc that goes from a temperature change of -20°F to
80°F - Answer 10.15
For photovoltaic systems, what cannot be connected to the supply side - Answer A non-
overcurrent light/device
Pool pump receptacles must be at least _ feet from the inside of a pool - Answer 10 feet
A boat hoist receptacle shall be mounted not less than ________ above the deck surface of the
pier and not below the electrical datum plane on a fixed pier - Answer 12 inches
When a metal enclosure is required to protect the grounding electrode conductor, the
enclosure has to be bonded to what at both ends? - Answer Grounding electrode conductor
Where a portable optional standby source is used as a ________ it shall be grounded to a
grounding electrode - Answer Separately derived system
In general care areas, patient bed locations shall be provided with a minimum of _ receptacles -
Answer 8 for general
14 for critical
What type of cable can't be used as a ground for critical and EM branch circuits of a hospital -
Answer Isolated ground
Master or journeyman electrical license issued in Michigan expires _ of each year and must be
renewed within _. Not renewing in time may result in loss of license and additional fees -
Answer December 31st, 60 days
18 feet of show window requires how many receptacles above window - Answer 2
210.62
Only an _ who is licensed under this act shall install electrical wiring - Answer Individual
Rules governing installation, replacement, and alteration of electrical equipment are those