Master Electrician 211 Exam Actual Exam Preparation
Newest 2025/2026 Complete Questions And Correct
Detailed Answers (Verified Answers) |Newest
Version!!!
The disconnecting means for a multiwire branch circuit
shall open all ___ at the point of origin. - Answer-
ungrounded
The nominal voltage of branch circuit conductors in a
single-family dwelling shall not exceed ___ volts between
conductors. - Answer-120
In dwelling units, GFCI protection is required in ___. -
Answer-Bathroom
The requirements for the minimum number of branch
circuits in a dwelling is found in ___. - Answer-210.11
Arc-fault requirements for dwelling units are found in
Section ___. - Answer-210.12
,2|Page
Conductors supplying more than one receptacle for cord-
and-plug connected portable loads shall have an ampacity
of not less than ___. - Answer-the branch circuit rating
A single receptacle installed on a 20-ampere 120-volt
circuit shall have an ampere rating of ___. - Answer-20
A duplex receptacle installed on a 20-ampere branch
circuit shall have a minimum ampere rating of ___. -
Answer-15
In a single-family dwelling the receptacles shall be
installed so that no point measured along the floor line is
more than ___ft. to the nearest outlet. - Answer-6
In dwelling units, receptacles supplying countertops in the
dining room shall be installed so that no point along the
wall is more than ___ inches to the nearest receptacle. -
Answer-24
Although a residential basement is unfinished, the
homeowner wants several receptacles to be installed.
, 3|Page
These receptacles are required to be ___. - Answer-GFCI
Protected
Refer to Figure 108.010. This kitchen layout is in a
restaurant. If a receptacle is installed in countertop space
A, does the NEC® require it to be GFCI protected? -
Answer-yes
Refer to Figure 108.014. Where this kitchen is in a house,
which receptacles are required to be GFCI protected? -
Answer-2, 4, 11, 6, 7, 8 & 9 only
Per the NEC®, receptacles that are installed outdoors at a
fast food establishment ___ required to be GFCI
protected. These are accessible to the public. - Answer-
Are
Guest suites of hotels with permanent cooking provisions
shall be required to have AFCI protection for the bedrooms
according to ___ in the NEC®. - Answer-210.12(C)
In a dwelling, a single receptacle installed for the cord
connection to a dishwasher located 2 feet from a kitchen