LP Gas Master Qualifier: Dispensing Installation & Maintenance Exam Questions And Answers | 2025/2026 Latest Updated
LP Gas Master Qualifier: Dispensing Installation & Maintenance Exam Questions And Answers | 2025/2026 Latest Updated The point of transfer at a dispensing unit must be ____ from Public ways, including public streets, highways, thoroughfares, and sidewalks. A. 10 feet B. 15 feet C. 25 feet - answer-A. 10 feet Steel supports on vertical ASME containers shall be protected against fire exposure with a material having a fire resistance rating of a least _____, except that continuous steel skirts that have only one opening that is 18 in. or less in diameter shall have fire protection applied to the ______ of the skirts. A. 3 hrs; outside B. 2 hrs; outside C. 3 hrs; inside - answer-B. 2 hrs; outside Pressure relief devices installed in underground containers serving dispensing systems shall be piped vertically upward to a point at least _____ above the ground. A. 2 feet B. 6 feet C. 10 feet - answer-C. 10 feetA remote emergency shut off device for either the internal valve or emergency shutoff valve is required to be located not less than _____ or more than _____ from the liquid transfer point. A. 10 ft ; 50ft B. 10 ft; 100ft C. 3 ft; 100ft - answer-C. 3 ft; 100ft The markings for the switch or circuit breaker to shut off power in an emergency shall be visible from ________. A. The front entrance to the business B. The Point of Transfer C. An Orbital Space Station - answer-B. The Point of Transfer Flexible connectors used in the installation of pumps so that pump casing is not subjected to excessive strains transmitted to it by the suction and discharge piping shall not exceed ____ in overall length. A. 60 inches B. 36 inches C. 24 inches - answer-B. 36 inches Electrical Equipment install at vehicular fuel operations shall comply with the provisions of _________ and shall be approved for compliance with _______. A. NFPA 58 6.25.2.2 - NFPA 58 6.25.2.3; NFPA 70- NFPA 58 Table 6.25.2.2 B. NFPA 58 Annex B; Rule 5J-20.045 C. NFPA 58 6.25.2.3; State of Florida Electrical Codes - answer-A. NFPA 58 6.25.2.2 - NFPA 58 6.25.2.3; NFPA 70- NFPA 58 Table 6.25.2.2Liquid meters shall be installed in accordance with ______.
Geschreven voor
- Instelling
- LP Gas Master Qualifier
- Vak
- LP Gas Master Qualifier
Documentinformatie
- Geüpload op
- 25 november 2025
- Aantal pagina's
- 3
- Geschreven in
- 2025/2026
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
lp gas master qualifier dispensing installation
Ook beschikbaar in voordeelbundel