personnel- Exam with correct Answers
Save
Terms in this set (117)
A designated area outside of a building to which
building occupants are directed to report upon
implementation of partial or full evacuation in
Assembly Area
accordance with comprehensive fire safety and
emergency action plan or a fire and emergency
preparedness plan
As applied to fire protection devices, any device,
equipment or system that initiates system function as a
automatic result of a predetermined temperature rise, rate of
temperature rise, or combustion products, without the
necessity for human intervention
A written statement issued by the fire Commissioner
approving the operation of a central station, for which
Certificate of operation
such certificate is required by this code or the rules,
or the constructions codes
A group of M building housing separate mercantile
tenant spaces and/or other similar occupancies and a
common and a common pedestrian area. A covered
covered mall
mall does not include an exterior perimeter or tenant
space with direct pedestrian access to the covered
mall.
,Place of Assembly Safety A person holding a certificate of fitness for place of
Personnel assembly safety personnel
The individual identified in a fire safety and evacuation
FSP Staff plan as responsible for the implementation of such
plan
Any building designed or constructed in accordance
with the 1968 Building Code, any prior Building Code,
High Rise Building
or other applicable laws, rules and regulations, that is
more than six stories or 75 feet/
A building or structure housing more than one
Mixed -Occupancy occupancy or type required by this chapter to
prepare an emergency plan
A biological, chemical, radio-logical or nuclear
incident or release; declaration of emergency plan by
Non-fire Emergency a lawful authority; explosion; medical emergency;
natural disaster; or other emergency affecting the
premises or the safety of building occupants
The fee owner or lessee of the building, or other
owner
person or entity having charge thereof.
A fire alarm systems having a feature that allows initial
fire alarm signal to sound in a constantly attended
central location and for which a human action is
subsequently required to achieve a general alarm, or
A pre-signal system
a feature that allows the control equipment to delay
the general alarm by more than one minute ( but not
more than 3 minutes) after the start of the alarm
processing
The precaution of directing building occupants to
Shelter in place remain indoor, at their present location, in response to
a fire or non-fire emergency.
A fire system, other than a mist fire extinguishers
Sprinkler System
system, that utilizes water as the extinguishing agent
, Piping indicating the need for action in connection
with the supervision of guard tours, fire extinguishing
Standpipe System
systems or equipment, fire alarm systems or the
maintenance features of related systems
The ability to communicate to the occupants of a
Voice Communication
building or occupancy by means of a fire alarm
Capability
system with one way or two- way voice
The use of the world "should" throughout these study
materials generally refers to policies, procedures
Should
and/or best practices recommended by the FDNY,
and may not be a codified requirement
Fire alarm system has two way voice communication
systems with warden hone
Fire alarm system with one and/ or two way
FLSD communication installed in a hotel building contains
50 or more sleeping rooms above floor
Fire Alarm system installed in a commercial/mixed
high rise building
Fire Alarm system in a homeless shelter not required
F-80
FLSD
Fire Alarm system with one way commuication system
( public announcement system), not requiring an
FLSD/F-80
F-53
Supervise the Fire Alarm Panel and communicate the
required information to the occupants on the
premises
Fire alarm system without voice communication
S-95
system and not requiring an FLSD/ F-80/ F-53