MASTER PLUMBER PAST BOARD EXAM QUESTIONS SET 1 AND ANSWERS /. Of the four board subjects given for Master Plumbers examination, which of this subject was originally split into two subjects? A. Plumbing Code B. Design and Installations C. Plumbing Arithmetic D. Practical Problems - Answer-D /.Copper tube and fittings used for drainage and vent piping installed aboveground shall be at least ____. A. Type DWV B. Type L C. Type K D. Type M - Answer-A /.A domestic dishwasher drain shall first connect to ____. A. an approved airgap fitting B. a double-check valve C. a triple-check valve D. an approved valve - Answer-A /.Unions shall be installed in a water supply system within ____ to a water heater A. 36 inches B. 12 inches C. 24 inches D. 48 inches - Answer-B /.A branch line serving a trap in a combination waste and vent system is required to be separately vented when the length of the branch exceeds ____. A. 15 B. 10 C. 5 D. 25 - Answer-A /.Three-inch horizontal drainage piping shall be run in practical alignment and at a uniform slope of not less than: A. 1/4 inch per foot B. 1/16 inch per foot C. 1/2 inch per foot D. 1/8 inch per foot - Answer-A /.The minimum requirement for the slope of horizontal drainage pipes between manholes is A. 4% B. 2-1/2 % C. 2% D. 3% - Answer-C /.A drain connecting the compartments of a set of fixtures to its trap is called a(an) ____. A. continuous waste B. special waste C. indirect waste D. combination waste and vent - Answer-A /.The maximum number of lavatories on a 2-1/2 inch horizontal waste line is ____. A. 10 B. 14 C. 20 D. 6 - Answer-B /.The maximum distance a gas shutoff valve may be from a gas appliance (except for range and dryer connectors) is ____. A. 6 feet B. 10feet C. 3 feet D. 2 feet - Answer-A /.An ejector discharge line shall be provided with a ____ A. gate valve only B. backwater valve and gate valve C. backwater valve only D. swing check valve and a globe valve - Answer-B /.In the water test of the entire plumbing system all openings should be tightly closed except at A. protruding cleanouts B. bleeders C. stack vent D. highest opening - Answer-D /.Because of structural conditions, a 4-inch house drain is installed with a slope of 1/8 inch per foot. This installation will result in a(an) ____. A. increased scouring and cleansing action B. reduction in fixture unit loading allowance C. separation of solids and liquid D. increased allowance in fixture unit loading - Answer-B /.A ____ may be installed with indirect waste A. water closet B. domestic kitchen sink C. drinking fountain D. lavatory - Answer-C /.A ____ trap is not self-cleaning A. plaster B. cast-iron C. bell D. grease - Answer-D /.Chemical or industrial liquid wastes that are likely to damage the public sanitary sewer system shall ____. A. be pretreated to render them innocuous B. not be used under any condition C. be drained into a holding tank D. be drained into a storm drain - Answer-A /.A seamless drawn-brass fixture tailpiece shall be ____. A. 24 B&S gauge B. 20 B&S gauge C. 22 B&S gauge

Show more Read less
Institution
MASTER PLUMBER PAST BOARD
Course
MASTER PLUMBER PAST BOARD

Content preview

MASTER PLUMBER PAST BOARD
EXAM QUESTIONS SET 1 AND
ANSWERS


/. Of the four board subjects given for Master Plumbers examination, which of this
subject was originally split into two subjects?

A. Plumbing Code
B. Design and Installations
C. Plumbing Arithmetic
D. Practical Problems - Answer-✅D

/.Copper tube and fittings used for drainage and vent piping installed aboveground shall
be at least ____.

A. Type DWV
B. Type L
C. Type K
D. Type M - Answer-✅A

/.A domestic dishwasher drain shall first connect to ____.

A. an approved airgap fitting
B. a double-check valve
C. a triple-check valve
D. an approved valve - Answer-✅A

/.Unions shall be installed in a water supply system within ____ to a water heater

A. 36 inches
B. 12 inches
C. 24 inches
D. 48 inches - Answer-✅B

/.A branch line serving a trap in a combination waste and vent system is required to be
separately vented when the length of the branch exceeds ____.

A. 15
B. 10

,C. 5
D. 25 - Answer-✅A

/.Three-inch horizontal drainage piping shall be run in practical alignment and at a
uniform slope of not less than:

A. 1/4 inch per foot
B. 1/16 inch per foot
C. 1/2 inch per foot
D. 1/8 inch per foot - Answer-✅A

/.The minimum requirement for the slope of horizontal drainage pipes between
manholes is

A. 4%
B. 2-1/2 %
C. 2%
D. 3% - Answer-✅C

/.A drain connecting the compartments of a set of fixtures to its trap is called a(an) ____.

A. continuous waste
B. special waste
C. indirect waste
D. combination waste and vent - Answer-✅A

/.The maximum number of lavatories on a 2-1/2 inch horizontal waste line is ____.

A. 10
B. 14
C. 20
D. 6 - Answer-✅B

/.The maximum distance a gas shutoff valve may be from a gas appliance (except for
range and dryer connectors) is ____.

A. 6 feet
B. 10feet
C. 3 feet
D. 2 feet - Answer-✅A

/.An ejector discharge line shall be provided with a ____

A. gate valve only
B. backwater valve and gate valve
C. backwater valve only

, D. swing check valve and a globe valve - Answer-✅B

/.In the water test of the entire plumbing system all openings should be tightly closed
except at

A. protruding cleanouts
B. bleeders
C. stack vent
D. highest opening - Answer-✅D

/.Because of structural conditions, a 4-inch house drain is installed with a slope of 1/8
inch per foot. This installation will result in a(an) ____.

A. increased scouring and cleansing action
B. reduction in fixture unit loading allowance
C. separation of solids and liquid
D. increased allowance in fixture unit loading - Answer-✅B

/.A ____ may be installed with indirect waste

A. water closet
B. domestic kitchen sink
C. drinking fountain
D. lavatory - Answer-✅C

/.A ____ trap is not self-cleaning

A. plaster
B. cast-iron
C. bell
D. grease - Answer-✅D

/.Chemical or industrial liquid wastes that are likely to damage the public sanitary sewer
system shall ____.

A. be pretreated to render them innocuous
B. not be used under any condition
C. be drained into a holding tank
D. be drained into a storm drain - Answer-✅A

/.A seamless drawn-brass fixture tailpiece shall be ____.

A. 24 B&S gauge
B. 20 B&S gauge
C. 22 B&S gauge

Written for

Institution
MASTER PLUMBER PAST BOARD
Course
MASTER PLUMBER PAST BOARD

Document information

Uploaded on
December 19, 2025
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainariam Harvard University
Follow You need to be logged in order to follow users or courses
Sold
148
Member since
1 year
Number of followers
7
Documents
8375
Last sold
3 days ago

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Read more Read less
3.3

25 reviews

5
8
4
2
3
8
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.