Complete Test Bank Digital Radiography and PACS, 4th Edition. By Christi Carter, Beth Veale. (All Chapters, Latest Edition) Digital Radiography and PACS, 4th Edition provides the latest information on digital imaging systems. It offers tips on producing clear radiographic images, and helps you build skills in computed radiography (CR) and digital radiography (DR), as well as picture archiving and communications systems (PACS). Coverage also includes quality control and management guidelines for PACS, CR, and DR. Written by noted educators Christi Carter and Beth Veale, this book provides excellent preparation for the ARRT credentialing exam and for success as a practicing radiographer or technologist.

Meer zien Lees minder
Instelling
Digital Radiography And PACS
Vak
Digital Radiography and PACS

Voorbeeld van de inhoud

Complete Test Bank
Digital Radiography and PACS, 4th Edition
By Christi Carter, Beth Veale


(All Chapters, Latest Edition)

,Chapter 02: Digital Imaging Characteristics
Carter: Digital Radiography and PACS, 3rd Edition


MULTIPLE CHOICE

1. Multiple numeric values divided into an array of small elements capable of being processed is
the definition of images.
a. analog
b. digital
c. medical
d. radiographic
Answer: B OBJ: Differentiate between analog and digital images.

2. The continuous and varying levels of brightness and colors describe images.
a. analog
b. digital
c. medical
d. radiographic
Answer: B OBJ: Differentiate between analog and digital images.

3. Critical characteristics of a digital image include all of the following except
a. contrast resolution.
b. noise efficiency.
c. sample resolution.
d. dose efficiency of the receptor.
Answer: C OBJ: Differentiate between analog and digital images.

4. Which of the following statements is not true?
a. Matrix size can change without affecting the FOV.
b. FOV can change without affecting the matrix.
c. Changing the matrix or the FOV will change the size of the pixel.
d. Changing the matrix and the FOV will not change the size of the pixel.
Answer: D OBJ: Relate pixel size, matrix size, and FOV to each other.

5. Each square in a matrix is called a
a. matrix element.
b. picture element.
c. bit.
d. byte.
Answer: B OBJ: Define pixel and image matrix and characteristics of each.

6. The number of bits per pixel is known as bit
a. pitch.
b. depth.
c. height.
d. width.

, Answer: B OBJ: Define pixel and image matrix and characteristics of each.

7. If a pixel has a bit depth of 29, the number of gray tones that pixel can produce is
a. 256.
b. 512.
c. 1024.
d. 2500.
Answer: B OBJ: Define pixel and image matrix and characteristics of each.

8. The size of the pixel is determined by the
a. bit.
b. bit depth.
c. matrix.
d. byte.
Answer: C OBJ: Define pixel and image matrix and characteristics of each.

9. Which of the following statements is not true?
a. Exposure index refers to the amount of exposure to the patient.
b. Exposure index refers to the amount of exposure to the image receptor.
c. Exposure is not uniformly represented across manufacturers.
d. Exposure index standardization is beneficial to the technologist.
Answer: A OBJ: Discriminate between standard units of measure for exposure indicators.

10. The measurement for radiation that was incident on the image receptor for a particular
exposure is known as
a. Gy.
b. KSTD.
c. KIND.
d. KTGT.
Answer: C OBJ: Discriminate between standard units of measure for exposure indicators.

11. Deviation index is the difference between and expressed in logarithmic fashion.
a. actual exposure (KIND); target exposure (KTGT)
b. standard exposure (KSTD); actual exposure (KIND)
c. standard exposure (KSTD); target exposure (KTGT)
Answer: A OBJ: Discriminate between standard units of measure for exposure indicators.

12. Factors that can adversely affect the pixel values expressed in the deviation index include all
of the following except
a. gonadal shielding within the image.
b. a prosthesis within the image.
c. failure of the system to recognize the exposure indicator.
d. failure of the system to recognize the collimated border.
Answer: C OBJ: Discriminate between standard units of measure for exposure indicators.

13. How dark or light a digital image appears on a display monitor is known as

, a. density.
b. contrast resolution.
c. brightness.
d. spatial resolution.
Answer: C OBJ: Define image brightness.

14. The ability of a digital system to display subtle changes in shades of gray is called
a. image quality.
b. contrast resolution.
c. spatial resolution.
d. dynamic range.
Answer: B OBJ: Discuss the differences between spatial and contrast resolution.

15. The ability of an imaging system to demonstrate small details of an object is known as
a. image quality.
b. contrast resolution.
c. spatial resolution.
d. dynamic range.
Answer: C OBJ: Discuss the differences between spatial and contrast resolution.

16. A system’s ability to respond to varying levels of exposure, resulting in more detail, is
referred to as
a. spatial resolution.
b. dynamic range.
c. contrast resolution.
d. dynamic resolution.
Answer: B OBJ: Discuss the differences between spatial and contrast resolution.

17. “The sum of the components in a recording system cannot be greater than the system as a
whole” is a definition of
a. modulation transfer function (MTF).
b. enhanced visualization image processing.
c. digital image contrast and density latitude.
d. principles of contrast enhancement.
Answer: A
OBJ: Discuss the implications of image noise, MTF, and detective quantum efficiency.

18. A perfect image processing system would have an MTF of
a. 1%.
b. 10%.
c. 100%.
d. 1000%.
Answer: C
OBJ: Discuss the implications of image noise, MTF, and detective quantum efficiency.

19. The more light spread, the the MTF.
a. higher

Geschreven voor

Instelling
Digital Radiography and PACS
Vak
Digital Radiography and PACS

Documentinformatie

Geüpload op
26 december 2025
Aantal pagina's
105
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$18.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ExpertMercy Notes
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
112
Lid sinds
9 maanden
Aantal volgers
0
Documenten
300
Laatst verkocht
17 uur geleden
Expert\'s Conner

Hello,

3.6

14 beoordelingen

5
8
4
0
3
1
2
2
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen