ESCO Light Commercial Refrigeration (Excellence) Comprehensive Resource To Help You Ace Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS Guaranteed Pass First Attempt!! Current Update!! 1. The suction accumulator prevents flood back from which of the following? A. An undercharge of refrigerant B. An evaporator fan set too high C. Flooding after hot gas termination D. TXV bulb clamped too tight to the suction line - Correct Answer: C. Flooding after hot gas termination 2. When the compressor service valve is back seated, which port is closed? A. Outlet port B. Inlet port C. Service port D. Pilot port - Correct Answer: C. Service port 3. When work on a refrigerator is complete, the compressor service valves should be in what position? A. Back seated B. Front seated C. Cracked D. Midpoint - Correct Answer: A. Back seated 4. What type of oil is used with HFC refrigerant? A. Alkyl-benzene B. Mineral C. Flax seed D. Polyol Ester - Correct Answer: D. Polyol Ester 5. On an expansion valve refrigeration system, a low pressure control can indirectly be used for A. Overcharge protection B. High side cut out C. Control refrigerant flow rate D. Controlling box temperature - Correct Answer: D. Controlling box temperature 6. What valve is used to connect multiple evaporators of different temperatures to a single compressor? A. Crank case pressure regulator (CPR) B. Evaporator pressure regulator (EPR) C. Oil pressure regulator D. Head pressure regulator - Correct Answer: B. Evaporator pressure regulator (EPR) 7. What valve is used to prevent evaporator pressure from falling below a set limit? A. Crank case pressure regulator (CPR) B. Evaporator pressure regulator (EPR) C. Oil pressure regulator D. Head pressure regulator - Correct Answer: B. Evaporator pressure regulator (EPR) 8. What valve is used to control excessive pressure entering the compressor during a hot pull down? A. Head pressure regulator B. Evaporator pressure regulator (EPR) C. Crank case pressure regulator (CPR) D. Oil pressure regulator - Correct Answer: C. Crank case pressure regulator (CPR) 9. The oil return orifice inside a suction line accumulator is designed to A. Return oil only during the off cycle back to the compressor B. Maintain the same pressure in the evaporator to the inlet of the compressor C. Meter liquid refrigerant and oil at acceptable rate D. Equalize discharge and suction pressures during off cycle - Correct Answer: C. Meter liquid refrigerant and oil at acceptable rate 10. Why do suction line filter dryer's have two service ports? A. To help remove acid trapped in the dryer B. To enable checking pressure drop across the dryer C. One port is used for charging with liquid, the other is used for charging with vapour D. One port is used for adding oil, the other poor is used for adding vapor to the system - Correct Answer: B. To enable checking pressure drop across the dryer

Show more Read less
Institution
ESCO
Course
ESCO

Content preview

ESCO Light Commercial Refrigeration

(Excellence)

Comprehensive Resource To Help You Ace 2026-2027
Includes Frequently Tested Questions With ELABORATED
100% Correct COMPLETE SOLUTIONS Guaranteed Pass First
Attempt!! Current Update!!



1. The suction accumulator prevents flood back from which of the following?
A. An undercharge of refrigerant
B. An evaporator fan set too high
C. Flooding after hot gas termination
D. TXV bulb clamped too tight to the suction line

- Correct Answer: C. Flooding after hot gas termination


2. When the compressor service valve is back seated, which port is closed?
A. Outlet port
B. Inlet port
C. Service port
D. Pilot port

- Correct Answer: C. Service port


3. When work on a refrigerator is complete, the compressor service valves should
be in what position?
A. Back seated
B. Front seated
C. Cracked
D. Midpoint

,- Correct Answer: A. Back seated
4. What type of oil is used with HFC refrigerant?
A. Alkyl-benzene
B. Mineral
C. Flax seed
D. Polyol Ester

- Correct Answer: D. Polyol Ester
5. On an expansion valve refrigeration system, a low pressure control can
indirectly be used for
A. Overcharge protection
B. High side cut out
C. Control refrigerant flow rate
D. Controlling box temperature

- Correct Answer: D. Controlling box temperature
6. What valve is used to connect multiple evaporators of different temperatures to
a single compressor?
A. Crank case pressure regulator (CPR)
B. Evaporator pressure regulator (EPR)
C. Oil pressure regulator
D. Head pressure regulator

- Correct Answer: B. Evaporator pressure regulator (EPR)
7. What valve is used to prevent evaporator pressure from falling below a set
limit?
A. Crank case pressure regulator (CPR)
B. Evaporator pressure regulator (EPR)
C. Oil pressure regulator
D. Head pressure regulator

- Correct Answer: B. Evaporator pressure regulator (EPR)

,8. What valve is used to control excessive pressure entering the compressor
during a hot pull down?
A. Head pressure regulator
B. Evaporator pressure regulator (EPR)
C. Crank case pressure regulator (CPR)
D. Oil pressure regulator

- Correct Answer: C. Crank case pressure regulator (CPR)

9. The oil return orifice inside a suction line accumulator is designed to
A. Return oil only during the off cycle back to the compressor
B. Maintain the same pressure in the evaporator to the inlet of the compressor
C. Meter liquid refrigerant and oil at acceptable rate
D. Equalize discharge and suction pressures during off cycle

- Correct Answer: C. Meter liquid refrigerant and oil at acceptable rate

10. Why do suction line filter dryer's have two service ports?
A. To help remove acid trapped in the dryer
B. To enable checking pressure drop across the dryer
C. One port is used for charging with liquid, the other is used for charging with
vapor
D. One port is used for adding oil, the other poor is used for adding vapor to the
system

- Correct Answer: B. To enable checking pressure drop across the dryer

11. A thermostatic expansion valve (TXV) that creates an unstable suction
pressure is said to be
A. Flashing
B. Modulating
C. Hunting
D. Fractionating

- Correct Answer: C. Hunting

, 12. Head pressure control valves permit hot gas to travel directly to the
A. Condenser
B. Evaporator
C. Liquid receiver
D. TXV

- Correct Answer: C. Liquid receiver

13. Liquid slugging of the compressor can be caused by
A. Low oil
B. TXV hunting
C. High superheat setting
D. High ambient

- Correct Answer: B. TXV hunting

14. A severe evaporator freeze up may cause
A. High discharge pressure
B. High suction pressure
C. Liquid flood back
D. Damage to TXV

- Correct Answer: C. Liquid flood back
15. The oil separator is installed in the
A. Suction line
B. Discharge line
C. Liquid line
D. Hot gas bypass line

- Correct Answer: B. Discharge line

16. If an oil separator is not used,
A. Oil traps should be installed in all vapor carrying lines
B. The system should be charged with 1/2 quart more oil
C. The system should be charged with 1/2 quart less oil
D. The system should be charged with less refrigerant

Written for

Institution
ESCO
Course
ESCO

Document information

Uploaded on
March 27, 2026
Number of pages
115
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

€14,15
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NURSINGDICTIONARY Harvard University
Follow You need to be logged in order to follow users or courses
Sold
267
Member since
2 year
Number of followers
87
Documents
2863
Last sold
3 weeks ago
NURSING ENCYCLOPEDIA

As a Career Tutor, I understand the pressure of managing demanding coursework, exams, and practical requirements across multiple disciplines. These professionally organized revision materials are designed to support students in nursing, healthcare administration, business, information systems, Engineering, health, IT, or trade courses management programs by simplifying complex concepts and reinforcing high-yield academic content. The materials are developed to help students: Understand core theories and practical applications across Multiple Disciplines Review exam relevant content aligned with undergraduate and graduate curriculam To Strengthen critical thinking, analytical reasoning, and decision-making skills Save time with clear, structured summaries instead of overwhelming textbooks Prepare efficiently for tests, assignments, case studies, and professional exams Each resource is created with academic standards in mind, integrating real world examples, industry terminology, and evidence based concepts commonly required in professional programs. Whether you are studying nursing fundamentals, healthcare management, information systems, project management, business strategy, Engineering these materials provide focused, reliable support for academic success. These revision guides are ideal for: Nursing and allied health students Healthcare administration and public health students Business, MBA, and management students Information technology and information systems students, engineering, business, IT, or trade courses If you are looking for clear, student-friendly, exam-focused revision materials that support multiple career pathways, these resources are designed to help you study smarter, perform better, and stay confident throughout your academic journey. WISH YOU SUCCESS!!

Read more Read less
4,2

34 reviews

5
18
4
7
3
7
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions