Q: All fire alarm systems and supervising stations require _____________ hours of standby power?
Answer:
24 hours

Q: Commercial fire alarm (premises, remote, central, proprietary, auxiliary) require minutes of alarm
power?
Answer:
5 minutes

Q: Household fire alarm systems require minutes of alarm power?
Answer:
4 minutes

Q: Battery calculations require % of additional safety margin?
Answer:
20%

Q: Secondary power shall switch within seconds?
Answer:
10 seconds

Q: Supervisory signals shall indicate within seconds?
Answer:
90 seconds

Q: Trouble signals shall indicate within seconds?
Answer:
200 seconds

Q: Equipment shall operate at to % voltage at 32-120 deg F and 85% humidity?
Answer:
85-110%

,Q: True or False: Each floor shall be a separate zone?
Answer:
True

Q: True or False: If system serves multiple buildings, each building shall be zoned separately?
Answer:
True

Q: True or False: If system serves multiple buildings, all the buildings shall be zoned as one entity?
Answer:
False

Q: What class circuit? Redundant (return path), operates with single ground of open
Answer:
Class A

Q: What class of circuit? Single pat, operates up to single open, EOLR on IDC and NAC
Answer:
Class B

Q: What class of circuit? Multiple paths, no supervision of paths, operation verified by receipt of
signal
Answer:
Class C

Q: What class circuit? Fail-safe operation
Answer:
Class D

Q: What class circuit? No supervision
Answer:
Class E

Q: What class circuit? Class A SLC which operates with short, fault isolator per device
Answer:
Class X

,Q: What class circuit? Network (ethernet), dual cable/fiber to each ethernet device or segment.
Answer:
Class N

Q: The operable part of a manually actuated alarm initiating device shall be not less than inches AFF?
Answer:
42 inches

Q: The operable part of a manually actuated alarm initiating device shall be not more than inches
AFF?
Answer:
48 inches

Q: A manually actuated alarm initiating device shall not be more than feet from the exit?
Answer:
5 feet

Q: Rod and pipe electrodes shall not be less than feet in length?
Answer:
8 feet

Q: Smoke alarms and smoke detectors shall not be installed within a inch horizontal path from the
supply registers of a forced air heating or cooling system
Answer:
36 inch (3 feet)

Q: Wall mounted visible notification appliances should be mounted so that the entire lens is not less
than inches?
Answer:
80 inches

Q: Wall mounted visible notification appliances should be mounted so that the entire lens is not more
than inches?
Answer:
96 inches

, Q: In rooms that are low that do not allow for mounting over 80 inches, wall-mounted visible
notification appliances should be mounted inches from the ceiling?
Answer:
6 inches

Q: Ceiling mounted strobes are allowed if ceilings are under feet?
Answer:
30 feet

Q: A ceiling shall be treated as a smooth ceiling if the beams project no more than inches from the
ceiling?
Answer:
4 inches

Q: Spot-type heat detectors shall be located on the ceiling not less than inches from the sidewall?
Answer:
4 inches

Q: Spot-type heat detectors located on the sidewall shall be no greater than inches from the ceiling?
Answer:
12 inches

Q: Spot-type heat detectors located on the sidewall shall be no less than inches from the ceiling?
Answer:
4 inches

Q: The is/are responsible for keeping all installation documents related to their installations.
Answer:
System Owner

Q: Inspections, testing, or maintenance shall be permitted to be done by a person or organization
other then the owner if conducted under a .
Answer:
Written contract

Q: When are visible alarm notification appliances required to be tested?
Answer:

Written for

Institution
Nursing
Course
Nursing

Document information

Uploaded on
June 22, 2026
Number of pages
46
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

€11,58
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
HavenAcademy Stanford University
Follow You need to be logged in order to follow users or courses
Sold
253
Member since
2 year
Number of followers
15
Documents
6431
Last sold
1 month ago

4,5

88 reviews

5
64
4
14
3
3
2
2
1
5

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions