Q: The operable part of a manually actuated alarm initiating device shall be not less than inches AFF.
Answer:
42 inches

Q: Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than feet in
length?
Answer:
8 feet

Q: Smoke detectors should not be located in a direct airflow or closer than inches from an air supply
diffuser or return air opening?
Answer:
36 inches

Q: Consider the use of visible notification appliances. Wall mounted appliances shall be mounted
such that the entire lens is not less than inches above the finished floor?
Answer:
80 inches

Q: How many 16 gauge conductors are permitted in a 4 x 1 1/2 inches square box?
Answer:
12

Q: Wall mounted audible appliances shall have their tops above the finished floors at heights of not
less than inches and below the finished ceilings at distances of not less than 6 inches?
Answer:
90 inches

Q: A minimum db ambient sound level with a 6 hour exposure time requires hearing protection?
Answer:
92 db

,Q: Spot type heat sensing fire detectors shall be located on the ceiling not less than inches from the
sidewall.
Answer:
4 inches

Q: While operating an aerial lift, the use of a body harnes and is not required?
Answer:
Stabilizer Hook, Grounding Pole, Insulation Mat

Q: Spot type smoke detectors shall be located on the ceiling or, if on a sidewall, between the ceiling
and inches down from the ceiling to the top of the detector.
Answer:
12 inches

Q: The distance between spot type heat detectors shall not exceed their listed spacing, and there shall
be detectors within a distance of the listed spacing, measured at right angles from the walls?
Answer:
One Half

Q: Where partitions extend to within percent of the ceiling height, the spaces separated by the
partitions shall be considered as separate rooms?
Answer:
15 percent

Q: Consider 1,000 feet total of 18 gauge soild coated copper at 167o Fahrenheit. The resistance of
this conductor is ohm?
Answer:
8.08 ohm

Q: Consider the installation of heat detectors on a ceiling with beams. A ceiling shall be treated as a
smooth ceiling if the beams project no more than inches below the ceiling?
Answer:
4 inches

Q: Which of the following conductor types is an acceptable substitute for FPLR?
Answer:
FPLP, CMP

, Q: Consider the use of PLFA fire alarm cable. The size of conductors in multiconductor cable shall
not be smaller than AWG?
Answer:
26 AWG

Q: You are using a power tool that has a 3 prong (grounded) plug. The only outlets available are 2
prong (non grounded). What can be done?
Answer:
Locate a 3 prong plug or used a tool with a 2 prong plug.

Q: The power source for a power limited fire alarm circuit shall be a listed PLFA or Class
transformer?
Answer:
Class 3 transformer

Q: Which of the following is a symptom of heat stroke?
Answer:
Red skin, Elevated Body Temperature, Rapid, Weak pulse

Q: The maximum number of 14 AWG, RHH conductors permitted in 1/2 inch EMT is ____ ?
Answer:
4

Q: The distance between smoke detectors shall not exceed a nominal spacing of feet?
Answer:
30 feet

Q: A portable ladder shall support at least times the maximum intended load.
Answer:
3.3 times

Q: Consider smoke detector placement on a peaked ceiling. Detectors shall first be spaced and
located within feet. of the peak, measured horizontally?
Answer:
3 feet

Written for

Institution
Nursing
Course
Nursing

Document information

Uploaded on
June 22, 2026
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

€11,58
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
HavenAcademy Stanford University
Follow You need to be logged in order to follow users or courses
Sold
253
Member since
2 year
Number of followers
15
Documents
6431
Last sold
1 month ago

4,5

88 reviews

5
64
4
14
3
3
2
2
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions