fire department connection Ans: normally on exterior of
building... FDNY can pump supplemental water into the
sprinkler system, standpipe, or other system furnishing
water for fire extinguishment to supplement existing
water supplies.

system control valve Ans: valve controlling flow to water-
based fire protection systems.

fire command center Ans: Designated room or area in a
structure where the status of the fire detection, alarm,
and protection systems is displayed and the systems can
be manually controlled.

Fire pump, automatic standpipe. Ans: A fire pump
located at or below street level that supplies the lower
300 feet (91.4 m) of a standpipe system or a combined
standpipe and sprinkler system.

tags Ans: on closed section valves serving affected areas:
area affected, brief description, occupancy classification,
c of f number, estimated time until operational




© 2025 All rights reserved

, 2 | Page



Green tag Ans: no impairment found in entire system-
main control valve

red tag Ans: place on main control valve if FULLY out of
service... put sprinkler company name, date of removal
from service and anticipated time to operational

blue disk Ans: partially out of service- on all fire
department connections

water storage tank Ans: Collects cooled water

OS & Y valve Ans: indicating type of control valve used
for fire sprinkler system

deluge valve Ans: water supply control valve intended to
be operated by actuation of an automatic detection
system that is installed in the same area as the discharge
devices. INTENDED USE IS MANUAL AND AUTO

deluge sprinkler system Ans: employing open sprinklers
that are attached to a piping system that is connected to
a water supply through a valve that is opened by the
operation of a detection system installed in the same
areas as the sprinklers. WHEN IT OPENS, water flows into
the piping system and discharges from all sprinklers
attached.

Early suppresion fast response sprinklers Ans: fast
response sprinkler that is listed for its capability to
provide fire suppression of specific high challenge fire
hazards


© 2025 All rights reserved

, 3 | Page



extra large orifice sprinklers Ans: = or > 1 inch less
pressure to achieve a given discharge density

extended coverage sprinkler Ans: 400 max square feet
discharge 20 foot by 20 foot spacing between sprinklers

fire pump Ans: a provider of liquid flow and pressure
dedicated to fire protection. A fire pump is a part of a
fire sprinklers system water supply and can be powered
by electric, diesel or steam. connected to public water
source or tank. provides higher pressure to sprinkler
system

Glass bulb sprinkler Ans: operated by heat breaking a
glass bulb filled with a non freezing liquid with diameters
that vary form 3 mm for quick response to 5 mm for
standard response

hose valve Ans: valve to additional hose connection

hydraulic placard Ans: sign attached to a hydraulically
calculated sprinkler system indicating the design density,
required gallons per minute and pressure for the system
to operate properly

hydraulically calculated systems Ans: method of sizing
auto sprinkler piping using a prescribed amount of water
to be distributed over a specific area.

impairment coordinator Ans: in charge of safety during
out of service systems




© 2025 All rights reserved

, 4 | Page



intermediate level sprinkler Ans: sprinkler equipped with
integral shields to protect the operating elemtn form
discharge from sprinklers installed at higher elevations

large orifice sprinkler Ans: sprinkler head with orifice
size equal or greater than 3/4 and less than 1 inch

listed device Ans: A fire protection component that has
been tested to perform under parameters specified for its
use by a nationally recognized testing agency.
Underwriter's Laboratory (UL) and Factory Mutual (FM)
are the two most common.

Master Pressure Reducing Valve Ans: A pressure reducing
valve installed to regulate pressures in an entire fire
protection system and/or standpipe system zone.

Main Drain Ans: The primary drain connection located on
the system riser and also utilized as a flow test
connection.

Microbiologically Influenced Corrosion (MIC) Ans:
Corrosion caused by the presence of microbes in the
water supply that over time attack the interior of metallic
piping and cause leaks, pitting, and blockages.

Old-Style/Conventional Sprinkler Ans: A sprinkler that
directs 40% to 60% of the water initially in a downward
direction and is designed to be installed with the
deflector in either the upright or pendent position.




© 2025 All rights reserved

Geschreven voor

Instelling
S-12 CITYWIDE SPRINKLER
Vak
S-12 CITYWIDE SPRINKLER

Documentinformatie

Geüpload op
5 januari 2026
Aantal pagina's
54
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,12
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Axpert NURSING
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
540
Lid sinds
2 jaar
Aantal volgers
167
Documenten
28074
Laatst verkocht
15 uur geleden
Study Smart

Your one-stop resource for high-quality, exam-focused study materials. Here, you'll find expertly crafted summaries, past exam papers, notes, and assignments tailored to help you succeed in your courses. Every document is written with clarity, accuracy, and exam performance in mind—saving you hours of studying and helping you boost your grades. ✅ Clear and well-structured content ✅ Covers key exam topics and common questions ✅ Trusted by students for academic success ✅ Instant downloads and affordable prices Whether you're cramming for finals or just staying ahead in class, my materials are designed to make your studying smarter, not harder. Take a look around and get the edge you need!

Lees meer Lees minder
3,8

124 beoordelingen

5
55
4
26
3
22
2
4
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen