Ace your NATE (North American Technician Excellence) Heat Pump certification exam with this definitive 2026/2027 guide. It features the actual exam with 100% verified questions and correct answers, covering system components, installation, charging, troubleshooting, electrical diagrams, and EPA regulations. Your key to earning industry-recognized HVAC certification and a top score.

Meer zien Lees minder
Instelling
Nate Heat Pump Service
Vak
Nate heat pump service

Voorbeeld van de inhoud

NATE Heat Pump Exam ACTUAL
EXAM 2026/2027: 100% Verified
Questions & Correct Answers

Question 1: A technician is troubleshooting a heat pump system in heating mode. The outdoor
ambient temperature is 35°F, and the system is experiencing low suction pressure. The refrigerant
line temperature at the outdoor coil outlet is 28°F. What is the most likely cause?

A. Overcharged system
B. Restricted outdoor coil airflow
C. Failed reversing valve


D. Defective compressor

Correct Answer: B


Rationale: Low suction pressure with a refrigerant line temperature below freezing indicates
insufficient heat transfer at the outdoor coil, typically caused by restricted airflow from dirty coils,
blocked fan, or debris accumulation.




Question 2: During heat pump installation, the technician measures 240V between L1 and L2 at
the outdoor unit contactor, but 0V between L1 and ground. What should be the immediate action?

A. Replace the contactor
B. Check the main electrical panel for a tripped breaker or loose neutral
C. Replace the transformer

,D. Check the thermostat wiring

Correct Answer: B


Rationale: Zero voltage between L1 and ground indicates a missing neutral connection or tripped
breaker, which is a safety hazard that must be addressed before proceeding with system operation.




Question 3: A heat pump system has a measured superheat of 3°F in cooling mode with proper
airflow. The manufacturer specifies 10-12°F superheat. What is the most appropriate adjustment?

A. Add refrigerant
B. Remove refrigerant
C. Replace the expansion valve


D. Increase blower speed

Correct Answer: B


Rationale: Low superheat indicates overcharge condition. Removing refrigerant will increase
superheat to the manufacturer's specified range, ensuring proper system operation and
compressor protection.




Question 4: During defrost cycle initiation, the technician observes that the outdoor fan continues
to run. What component failure would cause this condition?

A. Defrost thermostat
B. Defrost relay contacts welded closed
C. Reversing valve solenoid


D. Outdoor fan motor capacitor

Correct Answer: B

,Rationale: The defrost relay should de-energize the outdoor fan during defrost. Welded contacts
prevent the relay from opening, causing the fan to continue running when it should be off.




Question 5: A heat pump operating in heating mode has a discharge air temperature of 85°F with
70°F return air. The outdoor temperature is 40°F. What does this indicate?

A. Normal operation
B. Supplemental electric heat is energized
C. Reversing valve stuck in cooling position


D. Low refrigerant charge

Correct Answer: B


Rationale: A 15°F temperature rise is excessive for a heat pump alone at 40°F outdoor
temperature, indicating that supplemental electric heat is operating, either due to thermostat
setting or control logic.




Question 6: The technician measures 24VAC at the reversing valve solenoid but the valve does not
shift. What is the most likely cause?

A. Low refrigerant charge
B. Defective reversing valve solenoid coil
C. Failed defrost control board


D. Restricted liquid line drier

Correct Answer: B


Rationale: Proper voltage at the solenoid with no valve movement indicates the solenoid coil is
defective. The coil creates the electromagnetic field needed to shift the valve's internal slide
mechanism.

, Question 7: During heat pump startup in cooling mode, the technician notices the suction pressure
immediately drops to 30 psig and remains there. The outdoor temperature is 85°F. What is the
likely problem?

A. Overcharged system
B. Restricted metering device
C. Oversized system


D. Defective compressor valves

Correct Answer: B


Rationale: An immediate and sustained low suction pressure indicates a restriction in the
refrigerant flow, most commonly at the metering device, preventing proper refrigerant circulation.




Question 8: A homeowner reports insufficient heating. The technician finds the heat pump running
continuously with outdoor coil heavily frosted. The defrost thermostat contacts are closed. What
should be checked first?

A. Reversing valve operation
B. Defrost control board timing and operation
C. Refrigerant charge level


D. Outdoor fan motor amperage

Correct Answer: B


Rationale: Heavy frost accumulation with closed defrost thermostat contacts suggests the defrost
control board is not initiating defrost cycles, indicating a control board malfunction or incorrect
timing settings.

Geschreven voor

Instelling
Nate heat pump service
Vak
Nate heat pump service

Documentinformatie

Geüpload op
24 januari 2026
Aantal pagina's
44
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€13,15
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STUDYACEFILES (self)
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
71
Lid sinds
2 jaar
Aantal volgers
5
Documenten
1725
Laatst verkocht
1 dag geleden
StuviaNurseVault

Welcome to StuviaNurseVault!

4,0

12 beoordelingen

5
5
4
3
3
3
2
1
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen