Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Plumbing Code Exam 2026 – Study Guide & Practice Questions

Beoordeling
-
Verkocht
-
Pagina's
66
Cijfer
A+
Geüpload op
06-02-2026
Geschreven in
2025/2026

Prepare for the 2026 Plumbing Code Exam with this comprehensive study guide. Includes practice questions, code review, and strategies to strengthen knowledge, improve accuracy, and pass your plumbing licensing exam with confidence.

Meer zien Lees minder
Instelling
Plumbing Code
Vak
Plumbing Code

Voorbeeld van de inhoud

Plumbing Code Exam 2026 1 of 66


A 2" copper-tubing cold water line shall be supported 10 feet
horizontally at intervals of __________.



104.2 A plumbing permit.

What does replacing plumbing fixtures require?


105.2.3 Inspection Requests 24 hours

The Authority Having Jurisdiction shall be permitted to require a
____________ notice before inspection.


310.1 Fittings Prohibited fitting

A side inlet quarter bend is an example of a __________.


310.7 Direction of Flow correct relationship

Valves, pipes, and fittings shall be installed in _________ to the
direction of flow.




2/5/2026 1

,Plumbing Code Exam 2026 2 of 66

312.9 Steel Nail Plates No. 18

Plastic and copper or copper alloy piping penetrating framing
members to within 1" of the exposed framing shall be protected
by steel nail plates not less than ____________ in thickness.


312.9 Steel Nail Plates 1 1/2"

Steel nail plates shall extend along the framing not less than
_____ beyond the diameter of the pipe and tubing.


312.10 Sleeves Concrete & masonry walls

Sleeves shall be provided to protect piping through what kind of
walls?


313.3 Suspended Piping At every joint

No-hub cast iron piping in 5' lengths, installed horizontally
above ground, shall be supported _________.


402.5 Setting 12

No urinal shall be set closer than _____ inches from its center to 24
a side wall or partition or closer than _____ inches from center
to center.




2/5/2026 2

,Plumbing Code Exam 2026 3 of 66

402.5 Setting 15

No water closet or bidet shall be set closer than _____ inches 30
from its center to a side wall or obstruction or closer than _____
inches center to center to a similar fixture.


402.5 Setting 24

The clear space in front of a water closet, lavatory, or bidet shall
be not less than _____ inches.


402.6.1 Closet Rings (closet flanges) Top of the closet ring

Closet bends or stubs shall be cut off so as to present a smooth
surface, even with the ____________.


402.6 Flanged Fixture Connections carrier fitting

Wall-mounted water closet fixtures shall be securely bolted to an
approved ______ ______. The connecting pipe between ______
______ and the fixture shall be an approved material and
designed to accommodate an adequately sized gasket. Gasket
material shall be neoprene, felt, or similar approved gaskets.


402.10 Slip Joint Connections 12" x 12" access panel

A bathtub with slip joint connections that will be concealed shall
be provided with a minimum ____________.


2/5/2026 3

, Plumbing Code Exam 2026 4 of 66

404.2 Overflows House or inlet side of the trap

The overflow pipe from a fixture shall be connected on the
_______________.


407.2 Water Consumption 2.2 gpm

The maximum water use allowed in gallons per minute (gpm) or 8.3 lpm
liters per minute (lpm) for lavatory faucets, kitchen faucets, and
replacement aerators is _____ gpm/ _____ lpm

WSA: Washington State Amendments


407.2 Water Consumption 0.5 gpm

The maximum water use allowed in gallons per minute (gpm) or 1.9 lpm
liters per minute (lpm) for public lavatory faucets other than
metering is _____ gpm/ _____ lpm

WSA: Washington State Amendments


407.4 Metering Valves spring

Lavatory faucets located in restrooms intended for use by the water pressure
general public shall be equipped with a metering valve designed
to close by __________ or __________ when left unattended Exception: 1. Where designed and installed for use by persons with disability 2. Where
(self-closing). installed in day care centers, for use primarily by children under 6 years of age

WSA: Washington State Amendments


2/5/2026 4

Geschreven voor

Instelling
Plumbing Code
Vak
Plumbing Code

Documentinformatie

Geüpload op
6 februari 2026
Aantal pagina's
66
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€19,57
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
kingdom
1,0
(1)

Maak kennis met de verkoper

Seller avatar
kingdom stuvia
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
6
Lid sinds
1 jaar
Aantal volgers
0
Documenten
886
Laatst verkocht
4 maanden geleden

1,0

1 beoordelingen

5
0
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen