Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

API 653 Recertification Quiz With 100% Correct Answers | Graded A+

Beoordeling
-
Verkocht
-
Pagina's
4
Cijfer
A+
Geüpload op
14-02-2026
Geschreven in
2025/2026

API 653 Recertification Quiz With 100% Correct Answers | Graded A+ Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? - answer-The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom shall be: - answer-examined using magnetic particle inspection, and defective areas repaired and re-examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film lining, the maximum inspection interval is: - answer-14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - answer-20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. - answer-may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - answer-45mm (1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the maximum initial inspection interval is: - answer-25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using which code? - answer-API RP 579, section 4, 5 or 6. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches thick below what minimum metal temperature ?preheat? - answer-200°FWhen evaluated an existing temperature services tank, which has a successful service history of operation but was not originally designed and constructed to the requirement of API 650, appendix M, which condition temperature has to be used? - answer-The max Operating Temperature shall not exceed the temperature at which the tank has successfully operated in the pass. Flange material used for tank repair and alteration shall meet the minimum requirements for the material specifications according to: - answer-The as built standard which is an advantage of thick film UN-REINFORCED linings ? - answer-Fast curing and can be put back in service after 24 hours at normal ambient temperature. The perimeter welds on a welded-on patch plate in the critical zone should be ? - answerTwo-pass and examined visually and by either MP or PT. Existent welds on a tank shell are found to e closer than allowed by API 650 (7th Edition). Under what conditions can these welds be considered to be acceptable for continued service? - answer-Examined by MP inspection with no rejectable indications. The requirements of which standard shall be considered in the evaluation and alteration to the tank roof and roof-to-shell junction ? - answer-Current applicable standard Welding procedure for ladder and platform assemblies, but not their attachment to the tank? - answer-Shall comply with either AWS D1.1, AWS D1.6 or ASME Code Section IX. In floating roof tanks, shell nozzles without internal piping within operating range of the floating roof shall be supplied? - answer-Flush on the inside of the tank. The attachment welds of new lap-welded shell patch plates shall be examined by: - answerVisually and by either MP or PT What is the minimum external projection outside the shell for bottom plates in a new tank? - answer-2 inchesSubject to the purchaser's approval, where normalized plates are required? - answerThermo mechanical control process (TMCP) plates may be used. During welding operations the inspector should confirm - answer-The welding parameters are supported by the WPS and WPQ If a release prevention system utilizing a nonconductive, impervious external liner is installed under a new tank, what should be done? - answer-Anodes shall be placed between the external liner and the tank bottom in a conductive material. The activity that is used to a currently determine the remaining bottom thickness in areas where indications are found it is called? - answer-Sizing (Proc up) Minimum dimension of a shell flash patch? - answer-12" Max size of shell Lap-patch? - answer-48"x72" Minimum repair plate dimension? - answer-4" The likelihood of caustic stress corrosion cracking can be reduce by: - answer-Stress relieving Scribe the flexible joint across the two moving faces and raise end of swing line to check? - answer-Joints freedom of movement Minimum size of bottom lap-patch that does not cross a bottom seam? - answer-6" Minimum amount of shell UT on shell plate? - answer-At least 5 equally spaud areas for UT. On fixed roof, planks long enough to span at least - answer-Two roof raffer

Meer zien Lees minder
Instelling
Api 653
Vak
Api 653








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Api 653
Vak
Api 653

Documentinformatie

Geüpload op
14 februari 2026
Aantal pagina's
4
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€9,33
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SARAHnkalu West Virgina University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
29
Lid sinds
1 jaar
Aantal volgers
0
Documenten
2365
Laatst verkocht
1 week geleden
KnowledgeNest

I help students succeed with exams and practice tests . Learn smarter, practice more and ace your exams with confidence!!

4,6

7 beoordelingen

5
6
4
0
3
0
2
1
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen