ASPE CPD Exam
Study online at https://quizlet.com/_iqzv1j

1. 1. A 12‑story mixed‑use building will be supplied from C
a municipal main at 65 psi static. The top fixture is 135
feet above the meter and the design residual at the
top fixture is 15 psi. Ignoring friction for a first‑pass
check, what is the most reasonable design action?
A Add a single booster pump sized for 50 gpm at 30
psi
B Rely on city pressure with oversized mains
C Provide a booster system with at least one PRV‑-
zoned discharge header D Add PRVs only at the upper
floors

2. 2. You are selecting the diameter of a domestic cold B
water service using a fixture‑unit/peaking method.
The facility has highly intermittent, diversified loads.
Which design approach best reflects ASPE practice?
A Size strictly by connected load without peaking
B Use fixture units with a probabilistic peak flow curve
and check velocities C Use only the largest simultane-
ous gang restroom as the basis
D Base solely on meter size furnished by utility

3. 3. A vertical sanitary stack in a high‑rise needs a C
mid‑building horizontal offset around floor 16. What is
the primary hydraulic concern driving your detailing?
A Thermal expansion at the offset elbow
B Solids deposition due to reduced slope
C Positive/negative pressure transients and relief
venting across the offset D Condensation on pipe ex-
terior

4. B


, ASPE CPD Exam
Study online at https://quizlet.com/_iqzv1j

4. A hot water recirculation loop is failing to maintain
temperature at distal branches overnight. Pump is
running continuously. What is the most likely systemic
cause?
A Recirc pump oversized
B Return mains oversized and branches unbalanced
C Source mixing valve set too high
D Insulation too thick

5. 5. A roof uses controlled‑flow primary drains with B
overflow scuppers. During commissioning, ponding
reaches the structural live‑load limit before overflow
operates. Which is the most appropriate corrective
action?
A Increase overflow weir elevation
B Enlarge orifice plates in primaries to reduce ponding
rate
C Reduce primary strainer open area
D Remove orifices from primaries

6. 6. For a duplex sewage ejector serving a basement re- A
stroom group, what is the most critical control feature
to verify for reliability?
A Alternation of lead/lag with independent thermal
protection
B Single float switch for both pumps
C Manual start only
D Normally open check valves

7. 7. When reviewing pump curves, a designer notes B
the system curve shift after adding balancing valves.
Where does the pump operating point move?



, ASPE CPD Exam
Study online at https://quizlet.com/_iqzv1j

A Up and right to higher flow and head
B Down and left to lower flow and higher head
C Horizontally right to higher flow, same head
D Vertically down to lower head only

8. 8. A central heat‑pump water heater (HPWH) will be C
installed in a conditioned mechanical room. What co-
ordination issue is most important early in design?
A Copper vs. CPVC on DHW
B Return loop temperature sensor brand
C Room heat extraction and makeup air/ducting strat-
egy
D Aquastat setpoint calibration

9. 9. A lab tenant improvement includes acid waste from C
three sinks to the building sanitary. Which baseline
solution aligns with ASPE guidance?
A Schedule 40 PVC directly to sanitary
B No‑hub cast iron to sanitary
C PP or PVDF acid‑resistant piping to an in‑line or tank
neutralization system before sanitary
D Galvanized steel with epoxy liner

10. 10. In a high‑rise domestic water system with three B
PRV zones, field reports show pressure creep at night-
time. What's the first best step?
A Replace all PRVs with larger sizes
B Verify PRV downstream isolation/checks and inspect
for debris or seat wear
C Lower the building setpoint globally
D Increase pump VFD minimum speed

11. B

Geschreven voor

Instelling
ASPE CPD
Vak
ASPE CPD

Documentinformatie

Geüpload op
16 februari 2026
Aantal pagina's
26
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Gratis
Krijg toegang tot het volledige document:
Downloaden

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Docpower Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4017
Lid sinds
1 jaar
Aantal volgers
2
Documenten
1496
Laatst verkocht
18 uur geleden

2,8

8 beoordelingen

5
2
4
0
3
2
2
2
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen