SCOPE AND ADMINISTRATION
CH 1. Alternative materials, designs and methods of constructions and equipments
104.11 correct answers The provisions of this code are not intended to prevent the installtion of
any materials or to prohibit any design or method of construction not specifically prescribed by
this code, provided that any such alternative has been Approved. The building offical finds that
the proposed design is satisfactory and complies with the intent of the provisions of this code
SCOPE AND ADMINISTRATION
CH 1. Work Exempt from Permit
105.2 correct answers Permits shall not required for the following
BUILDING:
1. One Story Detached accessory, tools and storage sheds, playhouses, provided the floor area
not greater than 120 square ft
2.Fences not over 7 feet
3. Oil Derricks
4.Retaining Walls that are not over 4 feet
5.Water Tanks, capacity is not greater than 5,000 gallons
6.Sidewalks and driveways not more than 30 inches
7.Painting, papering, tiling, carpeting, cabinets, counter tops and similar finsh works
ELECTRICAL:
1.Repairs and maintenance: Minor repair work
2.Radio and televisions transmitting stations
3.Temporary testing systems: Permit shall not be required for the installtion of any temporary
system
GAS:
1. Portable heating appliance
2.Replacement of any minor parts that does alter approval of equipment that does not alter
approval and unsafe
MECHANICAL:
1. Portable heating, ventilation, cooling, evaprative appliance
2. Self-contained refrigeration system containing 10 pounds.
PLUMBING:
1. The stopping of leaks in drains, water, soil, waste or vent pipe
OCCUPANCY CLASSIFICATION AND USE
CH. 3 Low-hazazrd factory industrial, Group F-2
306.3 correct answers Factory industrial uses that invole the fabrication or manufacturing of
noncombustible materials that during finshing
- Beverages: up to snd including 16- percent alcohol
- Brick and Masonry
- Ceramic products
- Foundries
-Glass products
-Gypsum
, -Ice
-Metal product
OCCUPANCY CLASSIFICATION AND USE
CH.3 Mercantile Group M
309.1 correct answers Mercantile group M occupancy, the use of a building or structure or a
portion thereof for the display and sale merchandise, and involes stocks of goods
- Department stores
-Drug stores
-Markets
-Greenhouses for sale/display of plants that provides public access
-Gas stations
-Retails or wholesalesstores
-Sales rooms
OCCUPANCY CLASSIFICATION AND USE
CH.3 Utility and Miscellaneous Group U
312.1 correct answers Building and structures of an accessory character and miscellaneous
structures
-Agriculturals
-Aircrafts Hangers
-Barns
-Carports
-Fences more than 6 feet
-Grain Silos
-Livestock shelters
-Private Garages
-Retaining Walls
-Sheds
-Stables
-Tanks
-Towers
-Communication equipment structures
FIRE AND SMOKE PROTECTION FEATURES
CH.7 Combustible framing in fire walls
706.7 correct answers Adjacent combustible members entering into a concrete or masonry fire
wall from oppsite sides shall not have less than a 4-inch distance between embedded ends.
FIRE AND SMOKE PROTECTION FEATURES
CH.7 Fireblocks and draftstops in combustible construction
708.4.2 correct answers In combustible constructio where fire partitions do not extend to the
underside of the floor or roof sheating,decks, slab above, shall be provided with one pf the
following
1. Fireblocking up to the underside of the floor or roof sheathing, deck or slab above using
materials