Since 1992, the United States Department of Energy has required that all furnaces sold and installed
from that date on must have an AFUE of no less than:
A: 70%
B: 75%
C: 78%
D: 80%
- correct answer C: 78%
Many pre-1992 furnaces have efficiencies around _______.
A: 10%
B: 40%
C: 60%
D: 80%
- correct answer C: 60%
Today, furnaces with AFUE ratings greater than _____ are available.
,A: 85%
B: 90%
C: 100%
D: 110%
- correct answer B: 90%
A thermocouple is used with:
A: Intermittent pilot systems
B: Direct spark ignition systems
C: Glow coil ignition systems
D: Standing pilot ignition systems
- correct answer D: Standing pilot ignition systems
The purpose of the gas pressure regulator is to:
A: Keep the color of the flame constant
B: Keep the high limit switch from tripping
C: Maintain a constant gas pressure at the burner
, D: Allow the gas valve to operate smoothly and accurately
- correct answer C: Maintain a constant gas pressure at the burner
The instrument used to measure outlet gas pressure is the:
A: Velometer
B: Anemometer
C: Monometer
D: Draft gauge
- correct answer C: Monometer
The regulator on a natural gas furnace should be adjusted to supply _____ inches of pressure at the
burners.
A: 11"
B: 10"
C: 3.5"
D: 2"
- correct answer C: 3.5"
Burning one cubic foot of natural gas releases approximately _____ btu.
A: 800