QUESTION PAPER 2026 WITH ANSWERS
GRADED A+
◉ EPA recommends that we use XRF instruments for which HUD
and EPA have developed: Answer: Performance characteristics sheet
◉ When surfaces do not allow for use of an XRF, we should take
paint chips and send them to labs accredited by: Answer: The
National Lead Laboratory Accreditation Program (NLLAP)
◉ The degree of agreement of repeated measurements when using
an instrument, such as, an XRF is called: Answer: Precision
◉ Inspectors should check XRF's calibration at a minimum: Answer:
At the beginning of each inspection, every four hours during an
inspection, and at the end of each inspection.
◉ When is it advisable to group interior components with exterior
components for the purpose of testing for paint? Answer: We should
NEVER group interior with exterior.
,◉ For the purposes of a lead inspection our definition of multifamily
housing could include units of similar in construction when:
Answer: Any number of units built from 1960 to 1977.
◉ When performing an inspection an inspection for lead-based
paint, a testing combination is made up of the: Answer: Room
equivalent, component and substrate.
◉ Because walls have large areas and quantities of paint HUD
guidelines recommend testing: Answer: Each wall in each room
equivalent.
◉ When testing combination (e.g., door and jamb) are repeated
within a room equivalent, we should: Answer: Not test the same part
of the combination (door and jamb)
◉ We have found that we must inspect 49 units of 160-units
complex. Using a calculator's random number generator, we have the
random number 0.445. We have numbered the units sequentially,
what unit would we test? Answer: 72 (160 * 0.445 = 71.2 (Round
Up))
◉ If we wipe sample a window sill surface 2 inches by 24 inches and
find 80 ug of lead, how much lead do we have per square foot?
Answer: 240 ug (80/(2*24) * (144 in^2/ ft^2)
, ◉ EPA currently recommends that we respond to lead in bare soil
where children plan, if the levels are: Answer: 400 ug/g
◉ A laboratory reports that the amount of lead in soil is found to be
0.2%. We can convert this to ppm or ug/g which in this case would
be: Answer: 2,000 ug/g
◉ As part of our inspection report we should include a: Answer:
Table of the sample results listing findings by components, floor plan
of the house, and summary of positive findings.
◉ When procuring paint chip samples it is always important to:
Answer: Include all layers of paint equally in the sample.
◉ The CDC defines an EBL requiring an environmental investigation
as: Answer: 10 ug/dl
◉ A risk assessment differs from an EBL investigation because the
risk assessment focuses on : Answer: The cause of the child's EBL.
◉ According to _________, A structure in good condition may only
need a lead hazard screen risk assessment. Answer: HUD guidelines