QUESTIONS AND SOLUTIONS RATED A+
✔✔targets will be engaged only at ranges greater than or equial to _________ meters
with HE ammo. - ✔✔310 meters
✔✔who implements risk management in all phase of the training event? - ✔✔OIC
✔✔Ranger operation in countries with a permanent military presence will be conducted
according to this regulation/order DA PAM 385-63, and host nation regulation as
required by the provision of the ________ ________ _________ _________ normally
the ________ ________ apply. - ✔✔status of forces agreement (SOFA)
stricter regulation
✔✔who can approve the fire of ammo/explosives over any ammo storage area -
✔✔DCS/G3-5-7 ACSIM, or CMC for marines
✔✔firing through ________ will be avoided - ✔✔obstructions
✔✔when firing 40 mm HE ammo fireres will be in at least PPE Level - ✔✔1
✔✔how far must fires using a BFA be seperated from one another?
with a dispersion area of _______ degrees left and right of the GTL - ✔✔5 meters
10 degrees
✔✔what does the LSDZ cover - ✔✔Air to ground
ground to ground
✔✔can the RSO also be the ammo NCO on the range? - ✔✔NO
✔✔who ensures the RSO is physically present at the training site - ✔✔OIC
✔✔which sdz provides for greater containment of all ricochets? - ✔✔batwings
✔✔deviations are valid for - ✔✔1 year or less
✔✔who reports all accidents and ammo malfuntion to the range OIC - ✔✔RSO
✔✔what are the publications used for range safety - ✔✔AR 385-63
DA PAM 385-63
✔✔single hearing protection will be worn withing _______ meters of firing grenade
launchers - ✔✔2 meters
, ✔✔who inspects the instalation training complexes? - ✔✔the garrison safety manager -
army
instalation range operation director - marines
✔✔DA PAM 385-63 provides ________ requirements fo rthe US ARmy and marine
corps range safety programs - ✔✔minimum
✔✔any accident or incident ocuring under an approved deviation will cause _________
___________ of the deviation until an _________ is completed and the deviation
___________ by respected authority - ✔✔Automatic Termination
investigation
revalidated
✔✔the batwing SDZ will be considered for movement boxes for live __________
__________ and ________ ________ exercises - ✔✔fire manuever
fire movement
✔✔how often msut teh garrison safety officer inspect the instalation complex? and high
risk training operation? - ✔✔semi annually
quarterly
✔✔the standard _______ degree dispersion area for the SDZ may be reduced to
_______ degrees - ✔✔5 degrees
2 degrees
✔✔for live fire training operations conducted under an approved deviation by non
resident units, the host instalation _________, _________ _________ must approve
training at a _______ ________ - ✔✔commander/ senior commander
host instalation
✔✔distance x for non stabilized weapons will be equivalent to quadrant elevation of
________ degrees - ✔✔10 degrees
✔✔surface danger zone - ✔✔The ground and airspace designated within the training
complex (to include associated safety areas) for vertical and lateral containment of
projectiles, fragments, debris, and components resulting from the firing, launching, or
detonation of weapon systems to include explosives and demolitions.
✔✔dispersion area - ✔✔the area within the SDZ located between the GTL and the
ricochet area. this area accounts for human error, gun or canon tube wear, propellant
temperature, and so forth