1. All 15-ampere and 20-ampere, 125-volt general-purpose receptacles in a new
dwelling are required to be:
A) Grounding-type only
B) Duplex-type only
C) GFCI-protected
D) Installed 6 inches from the floor

Correct Answer: C
Explanation: The CEC requires GFCI protection for all 15A and 20A, 125V receptacles in
dwelling units in specific locations such as bathrooms, kitchens, outdoors, and unfinished
basements. This is a standard safety requirement for new dwellings .




2. Each multi-wire branch circuit MUST be provided with a means to disconnect all
ungrounded conductors:
A) Continuously
B) Safely
C) Individually
D) Simultaneously

Correct Answer: D
Explanation: Multi-wire branch circuits require a means to disconnect all ungrounded
conductors simultaneously to prevent the risk of returning current on the neutral when
only one phase is disconnected .

,3. What is the maximum percentage of the conductor rating at which an
overcurrent device must be set for conductors supplying a resistance welder?
A) 100%
B) 75%
C) 150%
D) 125%

Correct Answer: D
Explanation: For resistance welders, the overcurrent device may be set at up to 125% of
the conductor ampacity due to the intermittent nature of the load .




4. Which of the following is NOT allowed for connecting equipment grounding
conductors?
A) Machine screws
B) Terminal bars
C) Pressure connectors
D) Solder

Correct Answer: D
Explanation: Solder is not permitted for connecting equipment grounding conductors
because soldered joints can fail under high fault current conditions, creating a fire or shock
hazard .




5. Where flexible cord is connected to the building ceiling with a suitable "tension
take-up device," the maximum length of the cord from the supply joint to the
take-up device is _____ feet.
A) 6
B) 8
C) 4
D) 2

Correct Answer: D
*Explanation: The CEC limits the length of flexible cord from the supply point to a
tension take-up device to 2 feet (600 mm) to prevent strain on the connection points .*

,6. For a 14-gauge copper wire, the maximum overcurrent protection rating is _____
amps.
A) 30
B) 20
C) 15
D) 10

Correct Answer: C
Explanation: 14 AWG copper wire has a maximum overcurrent protection rating of 15
amperes under general use conditions. This is a fundamental code rule for conductor
sizing .




7. What is the minimum clearance required for overhead SERVICE-DROP
conductors over a roof with a slope of 6:12?
A) 3 feet
B) 4 feet
C) 8 feet
D) 6 feet

Correct Answer: B
*Explanation: For roofs with a slope of 4 in 12 or greater, the minimum vertical clearance
for service-drop conductors above the roof is 4 feet (1.2 meters) .*




8. _____ is defined as admitting close approach; not guarded by locked doors,
elevation, or other effective means.
A) Readily accessible
B) Isolated
C) Approachable
D) Accessible

Correct Answer: D
Explanation: "Accessible" means capable of being reached for operation, repair, or
inspection without the use of ladders or tools. This is a key CEC definition .

, 9. What is the minimum number of sealing fittings required for a 12-foot run of
horizontal conduit in a Class II, Division 1 location?
A) Four sealing fittings
B) One sealing fitting
C) Three sealing fittings
D) Two sealing fittings

Correct Answer: D
Explanation: In Class II, Division 1 locations (combustible dust), sealing fittings are
required on each conduit run entering an enclosure, typically at both ends of the run .




10. Fixed electric space heating loads shall be computed at _____ percent of the
total connected load.
A) 115%
B) 100%
C) 125%
D) 80%

Correct Answer: B
Explanation: Fixed electric space heating loads are calculated at 100% of the total
connected load, but the feeder load current cannot be less than the rating of the largest
branch circuit supplied .




Section 2: Conductors, Raceways, and Box Fill
11. The minimum trade size EMT required for a 45-foot run containing four #12
THHN/THWN, three #10 THHN/THWN, and two #6 THHN/THWN conductors is:
A) 1 inch
B) 1-1/4 inches
C) 3/4 inch
D) 1-1/2 inches

Geschreven voor

Instelling
ALBERTA MASTER ELECTRICIAN
Vak
ALBERTA MASTER ELECTRICIAN

Documentinformatie

Geüpload op
20 april 2026
Aantal pagina's
36
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€22,98
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
studyguidepro NURSING
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
204
Lid sinds
8 maanden
Aantal volgers
11
Documenten
2180
Laatst verkocht
2 dagen geleden
verified exams

Updated exams .Actual tests 100% verified.ATI,NURSING,PMHNP,TNCC,USMLE,ACLS,WGU AND ALL EXAMS guaranteed success.Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied. **Ace Your Exams with Confidence!**

3,8

40 beoordelingen

5
19
4
3
3
11
2
3
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen