Buckled interior baffles on a woodstove can:
A) admit access air
B) eliminate a flow reversal
C) inhibit the flow of gases out of the stove
D) reduce emissions - Answer-C) inhibit the flow of gasses
out of the stove
What level of inspection required every time you sweep a
chimney?
A) level I
B) level II
C) level III
D) level IV - Answer-A) Level I
The standard for solid fuel type room heaters is:
A) UL 103
B) UL 1482
,2|Page
C) UL 1777
D) UL 737 - Answer-B) UL 1482
The standard for factory built chimneys is:
A) UL 103
B) UL 127
C) UL 441
D) UL 641 - Answer-A) UL 103
The combustion process is referred to as the:
A) fire triangle
B) fire pyramid
C) square fire theory
D) fire tetrahedron - Answer-D) fire tetrahedron
Which of the following is a factor leading to greater
creosote accumulation?
A) higher smoke density
B) better insulated chimneys
C) smaller flues
,3|Page
D) smaller fuel loads - Answer-A) higher smoke density
At a minimum how much higher does a chimney need to
me than any point within 10 feet of the chimney?
A) 12 inches
B) 24 inches
C) 36 inches
D) 48 inches - Answer-B) 24 inches
OSHA requires that a ladder extend ____ inches above
the point of contact with the roof.
A) 12
B) 24
C) 36
D) 48 - Answer-C) 36
The three types of heat transfer are:
A) conduction, latent and radiation
B) radiation, convection, and sensible
C) sensible, radiant, and thermal
, 4|Page
D) radiation, conduction, and convection - Answer-D)
radiation, conduction, convection
During a level I inspection you would not be expected to
make a note of ____ in your report.
a) broken appliance parts
B) evidence of a smoking fireplace
C) lack of a fire stop
D) inadequate floor protection - Answer-C) lack of a fire
stop
The type of inspection performed shall be based on the:
A) circumstances that give rise to the inspection
B) date of construction
C) degree of access required to complete the inspection
D) inspectors analysis of the fuel supply - Answer-A)
circumstances that give rise to the inspection
If you encounter a down drafting chimney , you should
NOT :
A) open doors and windows in the home