U1 UST Installation/Retrofitting Questions And Answers U1 UST Installation/Retrofitting Questions And Answers U1 UST Installation/Retrofitting Questions And Answers U1 UST Installation/Retrofitting Questions And Answers U1 UST Installation/Retrofitting Questions And Answers U1 UST Installation/Retrofitting Questions And Answers U1 UST Installation/Retrofitting Questions And Answers

Meer zien Lees minder
Instelling
U1 UST Installation/Retrofitting
Vak
U1 UST Installation/Retrofitting

Voorbeeld van de inhoud

U1 UST Installation/Retrofitting Questions
And Answers

The regulations to enforce compliance of underground storage tank systems in the state are
found in?



a.) Code of Federal Regulations, 40 CFR Part 281

b.) California Code of Regulations, Title 23, Chapter 16

c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17

Correct Answer: b.




By definition an "underground storage tank system" includes

a.) The tank, all connected piping and dispensers

b.) The tank, all connected piping, ancillary equipment and containment system

c.) Only the tank

d.) Only tanks totally beneath the surface of the ground

Correct Answer: b.



(H&SC, Sec 25281(z))



Under-dispenser containment was required for all UST systems by ___________.

a.) December 31, 2003

b.) July 1, 1987

,c.) January 1, 1984

d.) January 1, 2000

Correct Answer: a.



CCR Title 23, Sec 2636(g)(C)

According to California Law, UST systems installed after July 1, 2003, require a one-time ELD test
to ensure that the tank is product tight...



a.) If the tank is located within one (1) mile of a public drinking water well

b.) If the tank is located within 1000 feet of a public drinking water well

c.) Unless the tank is equipped with secondary containment

d.) In all cases

For ALL tanks before use (H&SC 25290.2 (I))

Correct Answer: d.



H&SC, Sec 25290.2(i)

The written report submitted to the local agency after an unauthorized release is required to
include the following except:



a.) Description of actions taken to stop the release

b.) Cause of the release

c.) Method of disposal of released product

d.) Date on which the release was discovered

Correct Answer: b.



CCR Title 23, Sec 2652(c)

,An unauthorized release which does not escape from secondary containment only requires a
record on the operator's monitoring reports provided:



A. It did not increase the hazard of fire

B. It did not cause any deterioration of the secondary containment

C. It was cleaned up within 8 hours of detection

D. All of the above

Correct Answer: D.



H&SC, Sec 25294

The annual monitoring certification may be performed by:



A. A person possessing the appropriate contractors licenses

B. An individual trained and certified by the manufacturer of the monitoring equipment

C. A designated UST operator

D. A person who meets the requirements of both a and b

Correct Answer: D.



CCR Title 23, Sec 2715(i)

The following is true of secondary containment testing, EXCEPT:



a.) Must be tested every 24 months

b.) Must be tested every 36 months

c.) Results must be submitted to the local agency within 30 days of testing

d.) Local agency must be notified 48 hours prior to testing

Correct Answer: a.

, CCR Title 23, Sec 2637(a)

Records of cathodic protection system maintenance must be kept on file for ______________.



a.) 10 years

b.) 1.5 years

c.) 3 years

d.) 6.5 years

Correct Answer: d.



CCR Title 23, Sec 2712(b)

Impressed current cathodic protection systems shall be inspected no less than every
___________ to ensure that they are in proper working order:



a.) 60 days

b.) 90 days

c.) 30 days

d.) 120 days

Correct Answer: a.



CCR Title 23, Sec 2635(a)(2)

Monthly monitoring data must be kept on file for _________________.

a.) 3 years

b.) 6.5 years

c.) 5 years

d.) For the life of the UST system

Correct Answer: a.

Geschreven voor

Instelling
U1 UST Installation/Retrofitting
Vak
U1 UST Installation/Retrofitting

Documentinformatie

Geüpload op
20 mei 2026
Aantal pagina's
65
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€11,95
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LAUDABLETASKS1 EXAMS
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
79
Lid sinds
1 jaar
Aantal volgers
0
Documenten
250
Laatst verkocht
2 weken geleden

2,9

17 beoordelingen

5
5
4
1
3
3
2
4
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen