Improvement COMPLETE TEST BANK QUESTIONS AND
CORRECT DETAILED ANSWERS WITH RATIONALES
(CORRECT VERIFIED SOLUTIONS) A NEW UPDATED
VERSION |GUARANTEED PASS. 2026-2027
Dr. D. F. Deming's 14 principles of management emphasize:
a.
employee participation in a "customer-responsive" environment
b.
short-term goals and strong management
c.
individual performance, rather than teamwork
d.
setting of thresholds
e.
a and b
f.
c and d
ANS: A
The Deming principles of management emphasize CQI in a product
(service) through proactive employee participation in a "customer-
responsive" environment.
,Appropriate use of CQI assists the health care organization in responding
to all of the following except:
a.
increased competition
b.
escalating costs
c.
quality concerns
d.
development of individual performance
ANS: D
CQI focuses on and promotes teamwork rather than individual
performance.
Activity is defined as
a. rest mass is same as an electron but has a positive charge
b. product absorbed dose and QF
c. rate of nuclear decay
d. ionization per unit mass of air by photons
c. rate of nuclear decay
,The source of ionizing radiation that contributes the most to exposure of
the general population in the US is
a. medical procedures
b. nuclear power plants
c. natural background radiation
d. above ground nuclear testing
c. natural background radiation
Which type of device is best suited for output measurements of radiation
therapy equipment
a. TLD
b. ionization chamber
c. G-M detector
d. x-ray film
b. ionization
Stochastic or nonthreshold effects of radiation exposure do not include
a. cancer induction
b. cataract formation
c. genetic effects
d. birth defects
b cataract formation
, Exposure of which of the following people would contribute the most to
the genetically significant dose
a. 50 year old woman
b. 70 year old man
c. 20 year old woman
d. all equal
c. 20 yr old woman
The annual effective dose equivalent for radiation workers
a. .5 mSv
b. 5 mSv
c. 50 mSv
d. 500 mSv
c 50 mSv or 5 rem
A G-M detector is 2 m from a small brachytherapy source and measures an
exposure rate of 10mR/hr. What exposure rate would you expect to measure
if the detector were moved to 4 m from the source?
a. 5 mR/hr
b. 20 mR/hr
c. 2.5 mR/hr
d. 1 mR/hr
c. 2.5