DEX IOT Day 5 Exam A Grade Questions
and Verified Answers 100% Correct (New
2026- 2027 Update)
QUESTION
What position should the foot be in when tensioning the InternalBrace™ Ligament
Augmentation 2.0?
Neutral eversion only with 10 - 15° plantarflexion
Neutral inversion/eversion with approximately 30 - 35°
plantarflexion The position does not matter when tensioning
Neutral inversion/eversion with approximately 10 - 15°
plantarflexion Neutral inversion/eversion with approximately 10 -
15° dorsiflexion
Answer:
Neutral inversion/eversion with approximately 10 - 15° plantarflexion
QUESTION
True or False: The Talus Offset Guide should be placed at the 7:30 position for a left
foot and at the 4:30 position for a right foot.
Answer:
True
QUESTION
What product can be applied to the incision after the InternalBrace™ 2.0 ligament
augmentation Brostrom Repair has been completed to promote wound healing and
provide an anti-microbial environment?
TegaDerm™ Adhesive
Dressing Steri-Strips
JumpStart®
Dressing Non-stick
Bandage
Answer:
JumpStart® Dressing
,STUDOVA
QUESTION
True or False: The cage plate in the Mini Comprehensive Fixation System is Left and
Right Specific.
Answer:
false
QUESTION
Which modules in the Mini Comprehensive Fixation System house foot specific
plates? 1.0/1.4 mm & 2.0 mm
1.0/1.4 mm & 1.6 mm
1.6 mm & 2.0 mm
2.0 mm & 2.4 mm
Answer:
2.0 mm & 2.4 mm
QUESTION
True or False: Stadium caddy screw seating is a feature of the set.
Answer:
true
QUESTION
Which of the following terms is NOT used to describe the malposition of a fracture?
Angulation
Translation
Shortening
Comminution
Answer:
Comminution
,STUDOVA
QUESTION
True or False: The driver in the Mini Comprehensive Fixation System is placed in the
back of the screw holding sleeve to load properly.
Answer:
False
QUESTION
The VAL drill guide for the 1.0/1.4 instrument set provides a degree
cone. 30
24
20
12.5
Answer:
24
QUESTION
Which modules in the Mini Comprehensive Fixation System house reinforced straight
plates? 1.0/1.4 mm & 2.0 mm
1.0/1.4 mm & 1.6 mm
1.6 mm & 2.0 mm
2.0 mm & 2.4 mm
Answer:
2.0 mm & 2.4 mm
QUESTION
Which modules house the Rotation Correction plate in the Mini Comprehensive
Fixation System?
1.6 mm & 2.0 mm
1.4 mm & 2.0 mm
1.4 mm & 1.6 mm
, STUDOVA
1.6 mm & 2.4 mm
1.6 mm only
Answer:
1.6 mm & 2.0 mm
QUESTION
True or False: The torque limiting handle is calibrated for the 2.4 mm screws.
Answer:
true
QUESTION
What biologic product can be used as an augment during a Tibiotalar Minimally
Invasive Anterior Ankle Fusion procedure?
BoneSync™
StimuBlast®
AlloSync™
ArthroFLEX®
None of the
above
Answer:
AlloSync™
QUESTION
What portal is normally extended during a Tibiotalar Minimally Invasive Anterior Ankle
Fusion?
Anterior
Lateral
Medial
Neviase
r
None of the above
Answer:
Medial