2027 NEWEST UPDATE WITH COMPLETE QUESTIONS
AND CORRECT DETAILED ANSWERS\VERIFIED 100%
ALREADY GRADED A+
A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour basis of or
more
patients
ANSWERS: Four
Where installed to reduce electrical noise for electronic equipment,
electrical continuity of the metal raceways shall not be required
and metal raceway can terminate a (an) ____ nonmetallic fitting or
spacer on electronic equipment
ANSWERS: Listed fitting
,Feeder and branch circuit conductors within inches of a Ballast
shall
have an insulation temperature rating not lower than 90°C (194°F)
unless supplying a luminaiere marked as suitable for a different
insulation
temperature
ANSWERS: 3 inches
Manufactured wiring systems constructed with type MC cable
shall be supported and secured at intervals not exceeding
_________________________________________________ft.
ANSWERS: 6 ft
Where a main bonding jumper or a system bonding jumper is a
screw only the screw shall be identified with a ____ that shall be
visible with the screw installed
ANSWERS: Green finish
Plug fuses a 15 amperes and lower rating shall be identified by a ____
configuration of the window, cap, or other prominent part to
distinguish them from fuses of higher ampere rating
ANSWERS: Hexagon
,The load for household electric clothes dryer's in a dwelling
unit(s) shall be either ____ watts (volt-amperes) or the nameplate
rating, which ever is larger, for each dryer served ?
ANSWERS: 5000 watts
Service conductors installed as unjacketed multiconductor cable
shall have a minimum clearance of windows that are designed
to be opened,
doors, porches, stairs fire escape or similar locations.
ANSWERS: 3 ft (36 inches)
—— Cartridge fuses of the renewable type shall be permitted to be
used
only for replacement in existing installation is where there is no
evidence of over-fusing or tampering.
ANSWERS: Class H
Branch circuit conductors within ____inches of the ballast shall have
an insulation temperature rating not lower it 90°C 194°F
ANSWERS: 3" inches
, The minimum radius of a field bend on trade size 1 "1/4 RMC is ____.
ANSWERS: 8
In a dwelling unit which appliance is allowed to have a 24"inch cord
with Attachment ground plug ?
ANSWERS: Combination range hood/microwave oven
Type 3 Surge Protective devices can be installed on the load side of a
branch circuit overcurrent device up to the equipment served.if
_____________________________________________________________ the type
3 SPD connection must be a minimum 30'ft of conductor a
distance from the service or separately derived system
disconnect
ANSWERS: Included in the manufactures instructions
Which flexible cable is Allowed to be used for electric vehicle
charging station 300 Volts ?
ANSWERS: EVJ