NEWEST ACTUAL EXAM COMPLETE QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+||BRAND NEW!! 2026-2027
Indoor Electrical vehicle charging sites less specified listed for the
purpose of and location the couping means of the electrical
vehicle supply
equipment shall be stored located at the height of not less than
blank and no more than 4 feet
ANSWERS: 18"
AC or DC general use snap switches maybe use for control of
inductive loads not exceeding blank percent of the amperage
rating of the switch at the applied voltage
ANSWERS: 50 %
New York City Department of buildings approved manufacturing
wiring methods shall be used only for
ANSWERS: Lighting circuits above and accessible hung ceiling or
where no finished ceiling exists
, Type blank fuse adapters shall be designed so that once inserted in a
fuse holder they cannot be removed
ANSWERS: Type s
boxes installed in carnivals shall be designed so that no live parts
are
exposed to accidental contact. where installed outdoors the box
shall be a weatherproof construction and mountains so that the
bottom of the box is not less than blank above the ground
ANSWERS: 6"
What is the feeder or service calculation load for water disposal
940 VA dishwasher 1250 VA and a water heater 4500 VA
ANSWERS: 6690 va
,The number of receptacle outlets for guest rooms in hotels and
motels shall not be less than that require for a dwelling units.these
receptacles can't be located to be convenient for permit furniture
layout. but at least blank
receptacle outlet shall be readily accessible
ANSWERS: Two
And equal potential plane in an agricultural building shall be
connected to the electrical grounding system with a copper
insulated covered or bare
conductor and Not small then
ANSWERS: # 8
A door used by personnel to exit the workspace that is less than
25 feet from the workspace shall
ANSWERS: Swing outward with simple pressure
, the conductors use to connect the surge protection device to the
line or bus and to ground shall be any shall not be any longer than
blank and shall avoid unnecessary bends
ANSWERS: Necessary
Cables with entirely nonmetallic sheaths (Romex) shall be permitted to
enter the top of the surface mounted enclosure for one or more
non-flex race no less than
ANSWERS: 18"
According to the NEC bere live parts are guarded from the public
in the following methods except
ANSWERS: protected by fireproof curtain
Where angles or u pulls are made the distance between each
raceway entry inside the box and the opposite wall of the box shall
be not less than blank times the trade size of the largest raceway in
a row
ANSWERS: 6 times